Installation - urmet domus 1067 Quick Start Manual

8 inputs expansion module
Hide thumbs Also See for 1067:
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
GENERAL DESCRIPTION
WARNING: in this document there are only present some essential indications about product. For further
and detailed information, refer to manuals concerning 1067 and 1068 control units.
1067/008A is an expansion module provided with
8 inputs
1 balanced SAB input
3 outputs (1 relay output and 2 electric outputs)

INSTALLATION

In addition to inside the control panel, the 1067/008A expansion can also be installed inside a 1067/017
container (certified Grade 3).
WARNING! The absence of a casing certified Grade 2 or 3, results in the loss of EN50131 certification.
The tamper of the container must be connected to the SAB of the expansion. The expansion has terminals
for connecting the power supply, detectors, ad signalling devices, etc.
DESCRIPTION OF CONNECTION TERMINALS (Fig. 1)
Terminal /
Detail
Detail
+D
A
+V1
-V1
NC1
B
NO1
C1
U2
U3
+V2
-V2
IN1
IN2
IN3
C
IN4
IN5
IN6
IN7
IN8
D
SAB
Pushbutton
E
and
yellow LED
F
RUN
4
+
BUS Expansion unit power input via bus
BUS Data transmission/reception
D
BUS Expansion unit power input via bus
Power supply for output actuators (13,2 Vdc limited to 500 mA)
Relay output 1 – contact normally closed
Relay output 1 – contact normally open
Relay output 1 – common (max. 1 A - 24 Vdc)
Electric output 2 (current protected max. 10 mA)
Electric output 3 (current protected max. 10 mA)
Power to detectors connected to expansion unit (13.2 Vdc limited to 500 mA).
Four pairs of power terminals are connected to the expansion unit.
Alarm input no. 1
Alarm input no. 2
Alarm input no. 3
Alarm input no. 4
Alarm input no. 5
Alarm input no. 6
Alarm input no. 7
Alarm input no. 8
24h input (for system self-protection). It must always be BALANCED and
closed with a 2.7 kΩ balancing resistor
Device acquisition button and LED
Green LED to show working condition.
Slow blinking = normal operating conditions.
Fast blinking = no communication with unit for at least 1 minute.
:
Description
DS1067-005B

Advertisement

Table of Contents
loading

This manual is also suitable for:

1067/008a

Table of Contents