Whirlpool AKR 465/IX User And Maintenance Manual page 15

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
INSTALLATION - ASSEMBLY INSTRUCTIONS
The instructions below, to be carried out in the order in which they are numbered, refer to the drawings (giving the same numbering) on the last pages of this
manual.
1. Attach the hole diagram to the internal side of the wall unit, observing the positioning indications indicated on the diagram.
2. Drill the 3 holes as indicated on the diagram.
The largest hole is used to support the hood during fixture to the wall unit.
3. Repeat the operation to drill the other side of the wall unit.
4. Create an opening on the top of the wall unit, observing the dimensions indicated in the figure.
The opening will enable the passage of the fumes exhaust pipe and the electrical cable and will also facilitate any technical assistance required.
5. If the sides of the wall unit are 16mm thick, fit the 4 spacers (2 per side) in correspondence to the holes for the installation screws.
6. Using 2 screws, fit the collar next to the hood air outlet hole.
7. Pull out the steam deflector and remove the grease filter.
8. For Filter Version only - fit the deflector onto the collar (press-on).
9. For Extractor Version only - connect an exhaust pipe to the collar.
This pipe is not included with the standard fittings and must be purchased separately.
Note: if using pipes of diameter 120mm or 125mm, install the multi-connection flange to the collar.
10. Position the hood inside the wall unit, slotting the side tabs into the two holes (1 per side) prepared on the sides of the wall unit.
11. From inside the hood, tighten the 4 screws (2 per side) in correspondence to the holes prepared on the sides of the wall unit.
12. Carry out the electrical connection
13. For Extractor Version only - Duct the fumes exhaust pipe towards the outside.
14. Fit the front finish trim.
Note: the front finish trim is not supplied as standard and must be purchased separately; assembly instructions are provided with it.
15. To align the slide-out deflector, unscrew the 2 bottom screws, align the slide-out deflector with the wall unit, moving the 2 support brackets, then re-
tighten the 2 screws.
16. For Filter Version only - fit the carbon filter support and secure it with 2 screws.
Fit the carbon filter
17. Refit the grease filters.
Check hood operation, referring to the section giving a description of the hood and its use.
GB13

Advertisement

Table of Contents
loading

Table of Contents