Download Print this page

Specifications - ADC HiGain H2TU-C-388 List 7 Quick Installation

Line unit
Hide thumbs Also See for HiGain H2TU-C-388 List 7:

Advertisement

T
H2TU-C-388 L
HE
The H2TU-C-388 List 7 line unit is the Central Office (CO) side of a T1 transmission
system. The H2TU-C, when used with an H2TU-R remote unit, transmits a
1.544 Mbps payload on one unconditioned copper pair over the full Carrier Service
Area (CSA) range. The H2TU-C-388 List 7 is designed to mount in Double Dual
Module Plus (DDM+) high-density mechanics shelves.
F
EATURES
Front-panel features: craft port for maintenance
screen access, display panel for system status
reporting, status LED, and DSX-1 access jacks
HDSL2 transmission features:
• Full-duplex transmission on one copper pair
• Grounded loop detection on HDSL2 span
• Souces sealing current
Maintenance screens for inventory, provisioning,
performance monitoring, and troubleshooting,
including:
• Remote provisioning
S
PECIFICATIONS
Operating Temperature
Operating Humidity
HDSL2 Span Voltage
CO Supply
Mounting
HDSL2 Line Rate
HDSL2 Output
Maximum Insertion Loss
Maximum Loop Attenuation 28 dB
DSX-1 Line Rate
DSX-1 Line Format
DSX-1 Frame Format
DSX-1 Pulse Output
DSX-1 Input Level
7
IST
-40°F to +149°F (-40°C to +65°C)
5% to 95% non-condensing
0 or -180 Vdc ±5 Vdc
-48 Vdc nominal (-42.5 Vdc to -56.5 Vdc)
DDM+ high-density shelf
1.552 Mbps Overlapped Pulse Amplitude Modulation Transmission with
Interlocking Spectra (OPTIS)
+16.8 dBm ±0.5 dBm, 135Ω at CO side
+16.5 dBm ±0.5 dBm, 135Ω at remote side
35 dB @ 196 kHz; 135Ω
1.544 Mbps ±200 bps
Alternate Mark Inversion (AMI) or Bipolar with 8-Zero Substitution (B8ZS)
Extended SuperFrame (ESF), SuperFrame (SF), or Unframed (UNFR)
pk-pk
6 V
, pre-equalized for 0 to 655 feet of ABAM cable
+1.5 dB to -7.5 dB DSX
• Loop attenuation and insertion loss reporting
• Bit Error Rate Tester (BERT)
• Loss of Signal / Alarm Indication Signal
(LOS/AIS) payload alarm option
• Power Back Off (PBON and PBOC) for
configuring HDSL2 transmit power levels to
reduce crosstalk