REMOTE CONTROL OPERATION INSTRUCTIONS
NOTICE: ON/OFF rocker switch must be ON for the remote to
operate.
FEATURES:
Main Burner ON/OFF
Main Burner flame modulation (6 levels)
Choice of standing or intermittent pilot
Thermostat or Smart thermostat functions
On/Off relay*
Comfort Fan speed modulation (6 levels)
Accent Light modulation (6 levels)
THERMOSTAT
OFF/ON/SMART
REMOTE CONTROL INFORMATION
Supply Voltage: 4.5 V (three 1.5 V AAA batteries)
Ambient Temperature Ratings: 0 - 50°C (32 - 122°F)
Radio Frequency: 315 MHz
NOTICE: THE TRANSMITTER AND RECEIVER ARE RADIO
FREQUENCY DEVICES. PLACING THE RECEIVER IN OR
NEAR METAL SEVERELY REDUCES THE SIGNAL RANGE.
NOTICE: TURN "OFF" THE MAIN GAS SUPPLY OF THE APPLI-
ANCE DURING INSTALLATION OR MAINTENANCE OF THE
RECEIVER DEVICE.
NOTICE: FOR INSTALLATION/MAINTENANCE, SWITCH OFF
THE INSERT BY REMOVING MAIN POWER SUPPLY AND BAT-
TERIES IF INSTALLED.
41412-0-0120
TRANSMISSION
FLAME ON
COMFORT FAN
KEY LOCK
LOW BATTERY INDICATOR
ACCENT
LIGHT
Figure 57b
CPI Mode – In the "Pilot On Demand" mode, the pilot remains
ON continuously even when the burner is turned OFF. The pilot
will shut off after 7 days if there is no activity or call for heat.
•
FIRE HAZARD. Can cause severe injury or death.
•
The Transmitter causes ignition of the appliance. The
appliance can turn on suddenly.
•
Keep away from the appliance burner when operating
the remote system.
Blue LCD display
ON/OFF Button
THERMOSTAT Button
UP/DOWN Arrow Button
MODE Button
Figure 57a
ROOM
TEMPERATURE
CPI MODE
WARNING
Page 45