Specifications - Empire Comfort Systems White Mountain Hearth DVCX42FP91K-3 Installation Instructions And Owner's Manual

Direct-vent zero clearance decorative gas fireplace
Table of Contents

Advertisement

Input BTU/Hr Maximum
Input BTU/Hr Minimum
KWH (Maximum)
KWH (Minimum)
Orifice (Front / Rear)
Air Shutter Opening
Height without standoff
Width
Depth
Gas Inlet Shutoff Valve (pipe)
Vent Size
NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
NOTE: The glass used in your fireplace is ceramic glass. If the glass is cracked or damaged in any way, it should be replaced only with a
complete glass frame assembly from Empire. See parts list on Pages 52 - 55 for ordering.
GAS TYPE
Natural
Propane
NOTE: For gas pipe dimensions, see Page 13.
Page 6

SPECIFICATIONS

DVCX42NAT
40,000
27,000
11.72
7.91
44 / 40
3/16
36-7/8
43-5/16
21-1/16
1/2 NPT
5 x 8
GAS SUPPLY PRESSURES
MAXIMUM
14
14
FULL OPEN
MINIMUM
4.5
11
DVCX42LP
36,000
29,000
10.55
8.5
57 / 1.45
36-7/8
43-5/16
21-1/16
1/2 NPT
5 x 8
MANIFOLD
3.5
10
41412-0-0120