FUNCTIONING A FAILURE STATE SIGNALING VIA LED
ARMED
LED1
HEATING
LED2
SHOT
LED3
WASH
LED4
FORCED PAUSE
LED5
FAILURE
LED6
(RED)
When a failure occurs, the appliance will emit 10 beeps and repeat the signal every 60 min. until it is
restored.
Note. In case of "self-resetting" faults (battery or 220V missing) the sequence of the 10 Beeps may stop
earlier, so if the signals are irregular in the Beep number or the repetition, it means that we are in the
FIXED ON
SLOW FLASHING
FAST FLASHING
TURNED OFF
FIXED ON
CODED FLASHING
TURNED OFF
FIXED ON
ONE FLASH
TURNED OFF
FIXED ON
ON FLASH
TURNED OFF
FIXED ON
ONE FLASH
TURNED OFF
CODED FLASHING
SOUND FAILURE SIGNALING
presence of a "false contact" on the battery or on the 220V mains.
ARMED APPLIANCE
DISARMED APPLIANCE
DISARMED APPLIANCE BUT WITH ACTIVE BURNER
PREHEATING FUNCTION (50% of maintenance)
ALL THE RESISTANCES OFF
ALL THE RESISTANCES SELECTED ON
ONLY ONE RESISTANCE ON; THE NUMBER OF FLASHES =
RESISTANCE NUMBER
SHOT NOT ACTIVE
SHOT ACTIVE
TO EVERY REARMAMENT OF THE MACHINE
BURNER WASH NOT IN FUNCTION
BURNER WASH IN FUNCTION
TO EVERY REARMAMENT OF THE MACHINE
THE APPLIANCE IS NOT IN THE FORCED PAUSE STATE
THE APPLIANCE IS IN THE FORCED PAUSE STATE
(it will ignore every firing commands untili its end)
FOR EVERY RIARMAMENT OF THE MACHINE
NO ALLARM
N. 1 FLASH: LIQUID_LEVEL_ALARM
N. 2 FLAS: CARD_OVERHEATING_ALARM
N. 3 FLASH: BATERY_ABSENT_ALARM
N. 4 FLASH: DEFECTIVE_SONDE_ALARM
N. 5 FLASH: LACK_NETWORK_ALARM
N. 6 FLASH: BURNER_OVERHEATING_ALARM
N. 7 FLASH: PUMP_FAILURE_ALARM
N. 8 FLASH: RESISTANCE_FAILURE_ALARM
Need help?