It is possible to activate special functions that vary the operation of the two relay outputs and other functions such
as: the deactivation of network failure signal on the relay, deactivate the liquid control, activate a relay during firing,
deactivation of the burner washing cycle, "Bistable" shot mood, burner preheating (it is maintained at 50% of the
operating temperature during the disarming, this to speed up the resetting phase).
To access the "Menu 1" of Programming special functions you need:
1. Disconnect ARM and FOG
2. Note down the DIP-SWITCH configuration
3. Turn all DIP-SWITCH OFF
4. Remove the Jumper from BUZZ (J3)
5. Place the Jumper on J2
6. Set all DIP-SWITCHS to ON for the functions to be activated
7. Remove the Jumper from J2 and replace it on BUZZ (J3)
8. Restore the DIP-SWITCH as noted down before (point 2)
DIP-SWITCH
FUNCTIONING
LACK OF
OFF
NETWORK
ON
SIGNALING
OFF
LIQUID LEVEL
ON
CONTROL
STATE RELAY
OFF
LOGIC
ON
OFF
LIQUID LEVEL
ON
LOGIC
OFF
LIQUID/SHOT
ON
RELAY
OFF
SAVE PUMP
ON
OFF
DO NOT WASH
ON
OFF
BIESTABLE SHOT
ON
OFF
HEATING
PREHEATING
ON
SPECIAL FUNCTIONS - MENU 1
SPECIAL FUNCTIONS PROGRAMMING (J2 CLOSED)
DIP1
DIP2
DIP3
DIP4
OFF
X
X
X
ON
X
X
X
X
OFF
X
X
X
ON
X
X
X
X
OFF
X
X
X
ON
X
X
X
X
OFF
X
X
X
ON
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
DIP5
DIP6
DIP7
DIP8
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
OFF
X
X
X
ON
X
X
X
X
OFF
X
X
X
ON
X
X
X
X
OFF
X
X
X
ON
X
X
X
X
OFF
X
X
X
ON
X
X
X
X
X
X
X
X
DIP9
SETTING
X
LACK OF NETWORK SIGNALED ON
STATE RELAY
X
LACK OF NETWORK NON-SIGNALED
ON STATE RELAY
X
LIQUID LEVEL CONTROL ACTIVATED
(standard)
X
LIQUIDI LEVEL CONTROL
DEACTIVATED
X
RELE N.O.;
CLOSED IF ARMED
WITHOUT ALARMS
X
RELE N.O.;
CLOSED IF IN ALARM
X
RELE N.C.;
IT IS OPEN WHEN THERE
IS A LACK OF LIQUID (standard)
X
RELE NO.;
IT IS CLOSED WHEN
THERE IS A LACK OF LIQUID
X
RELAY USED AS LACK OF LIQUID
(standard)
X
RELE N.O.;
CLOSES WHEN
SHOOTING
X
SAVE PUMP FUNCTION DISABLED
X
SAVE PUMP FUNCTION ENABLED
X
WASH IF PROVIDED
X
WASH AUTOMATICALLY EXCLUDED
X
IMPULSE SHOT INPUT
X
BIESTABLE SHOT INPUT
OFF
PREHEATING FUNCTION DISABLED
ON
PREHEATING FUNCTION ENABLED