Page 1
IMPORTANT NOTICE Please read the Operating Manual carefully before attempting to install or service the air exhaust fan! AWENTA shall not be liable for any damage resulting from incorrect operation, non-intended use or unauthorized repair or modifications of the product.
Page 2
and/or mental abilities, and by people without any experience in or understanding of the operation of the product, if supervised or instructed by a competent adult in the safe use of the product so that they understand the relevant operating risks. This product is not a toy and children should not play with it.
• Never attempt to modify or alter the fan without authorization. • Before installing the fan, verify the load bearing capacity of the installation substructure. Improper installation fastening may result in damage or failure of the fan and hazards to the people nearby. The fan can be hazardous when operated against its intended use or installed by unqualified personnel.
- ammable contaminants, including gas, vapours, mists or particulates which may form explosive mixtures with air. • The control system must prevent extremely frequent power cycling. Transport and storage • Keep the air exhaust fans in their original packaging in a dry, sheltered room. •...
The air humidity sensor detects humidity between 40% (“HIGRO” potentiometer turned maximum to the left) and 90% (“HIGRO” potentiometer turned maximum to the right) of relative humidity. The system is additionally equipped with a timer. The operation of the fan depends on the power supply connection method. If connected as shown in Fig.4, the fan will start automatically when the air humidity level exceeds the set value of the humidity sensor.
Page 6
• Remove the electric cover (4) xed with screws (3). Applicable to the H version: A sensor is attached to the electric cover. Remove the cover carefully so as not to damage the wiring harness connecting the sensor to the controller. •...
First start Start the air exhaust fan only with all safety precautions in place and all hazards eliminated. Check that it runs steadily and the air is handled e ciently (out of the room and through the air exhaust ductwork to the outside). Check the operation of the fan (noise, vibration, the possibility to control the rotation speed).
• Do not attempt any maintenance when the air exhaust fan is running or at live voltage! • If excessive vibrations are felt or heard, have the technical inspection carried out by a quali ed electrician. • The maintenance intervals depend on the actual contamination of the fan rotor and must not be longer than 6 months! •...
Page 9
7. The warranty does not cover the installation or the maintenance of the product. 8. For all matters not provided for by this Warranty Certi cate, the Polish Civil Code (Articles 577- 582) shall apply. Do not dispose of waste electrical equipment with household waste. The crossed-out wheelie bin symbol on this product means that it is waste of electrical and electronic equipment (WEEE) at the end of its operating life and shall not be disposed with household waste.
Need help?
Do you have a question about the WPA110 and is the answer not in the manual?
Questions and answers