Download Print this page

Wolf 24 E Series Installation Manual page 4

Hide thumbs Also See for 24 E Series:

Advertisement

Available languages

Available languages

Specifications
Installation Requirements
The oven can be installed in a standard or flush inset
application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart.
For flush inset installations, a minimum 1/8"
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
Minimum Base Support
TRIM OVERLAP
Top
Bottom
Sides
4 | Wolf Customer Care 800.222.7820
Electrical Requirements
Installation must comply with all applicable electrical codes.
For ease of installation, the electrical supply for the oven
should be placed in an adjacent cabinet within reach of the
conduit.
Performance may be compromised if the electrical supply
is less than 240 volts.
reveal is
The oven is supplied with a conduit consisting of two hot
(3)
lead conductors and a ground conductor. The wiring dia-
gram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS
150 lb
Electrical Supply
(68 kg)
Service
1/8"
(3)
Conduit
0"
(0)
Total Amps
7/8"
(22)
Max Connected Load
Rating plate location
grounded, 240/208 VAC, 60 Hz
20 amp dedicated circuit
RATING PLATE
4'
(1.2 m)
16
3.6 kW

Advertisement