Internal CV Calibration
Press "KYBD + STEP" then power on device. All the sequencer LEDs will light up.
Press "Shift + STEP1" to start Internal CV calibration.
Wait for calibration to finish.
All of the sequencer LEDs will light up in sequence after this has finished.
Output CV Calibration
In this mode, these buttons have new functions:
There are four test modes A / B / C / D to be calibrated. Their target voltage is 0V / 1V / 3V / 5V respectively.
Button Name
HOLD/REST
RESET/ACCENT
ARP/SETEND
PATTERN/BANK
SHIFT
PAGE
PLAY/STOP
REC
Function
Select test mode A
Select test mode B
Select test mode C
Select test mode D
Save
page 3 of 5
page 3 of 5
Button Name
Function
STEP1
Select X1 (about ±1 mV)
STEP2
Select X2 (about ±4.5 mV)
STEP4
Select X3 (about ±9 mV)
STEP4
Select X4 (about ±45 mV)
STEP5
STEP6
STEP7
STEP8
KYBD
Decrease