2.4 Cooling and Heating Data Sheet in Rated Frequency
Cooling:
Rated cooling
condition(°C)
Model
(DB/WB)
Indoor
Outdoor
27/19
35/24
36K
Heating:
Rated heating
condition(°C)
Model
(DB/WB)
Indoor
Outdoor
20/-
7/6
36K
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 7.5 m.
Technical Information
Pressure of gas pipe
connecting indoor and
outdoor unit
P (MPa)
0.9 to 1.2
Pressure of gas pipe
connecting indoor and
outdoor unit
P (MPa)
2.0 to 2.5
40 to 39
Inlet and outlet pipe
temperature of heat
Fan speed of
exchanger
T1 (°C)
T2 (°C)
12 to 14
43 to 41
Inlet and outlet pipe
temperature of heat
Fan speed of
exchanger
T1 (°C)
T2 (°C)
2 to 5
Fan speed of
indoor unit
outdoor unit
Super High
High
Fan speed of
indoor unit
outdoor unit
Super High
High
Compressor
frequency
(Hz)
56
Compressor
frequency
(Hz)
60
5