Omega OTEC IEWQ Series Technical Manual page 16

High wall inverter
Hide thumbs Also See for OTEC IEWQ Series:
Table of Contents

Advertisement

button
6.
Press this button can select left & right swing angle. Fan blow angle can be selected circularly as below:
Note:
Press this button continuously more than 2s, the main unit will swing back and forth from left to right, and then loosen
the button,the unit will stop swinging and present position of guide louver will be kept immediately
Under swing left and right mode, when the status is switched from off to
status will switch to off status directly; if press this button again within 2s, the change of swing status will also depend on
the circulation sequence stated above.
button
7.
Press this button can select up & down swing angle. Fan blow angle can be selected circularly as below:
(horizontal louvers stops
at current position)
When selecting "
", air conditioner is blowing fan automatically. Horizontal louver will automatically swing up & down at
maximum angle.
When selecting "
position.
When selecting "
Hold "
" button above 2s to set your required swing angle. When reaching your required angle, release the button.
Note:
" may not be available. When air conditioner receives this signal, the air conditioner will blow fan automatically
"
Press this button continuously more than 2s, the main unit will swing back and forth from up to down, and then loosen
the button, the unit will stop swinging and present position of guide louver will be kept immediately.
Under swing up and down mode, when the status is switched from off to
status will switch to off status directly; if press
circulation sequence stated above.
8.SLEEP button
8
Press this button, can select Sleep 1 (
after electrified, Sleep Cancel is defaulted.
main unit setting temperature will increase 1 , two hours, setting temperature increa- sed 2
setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will decrease 1 , two hours,
setting temperature will decrease 2 , then the unit will run at this setting temperature.
Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
Sleep 3-the sleep curve setting under S leep mode by DIY;
(1)Under Sleep 3 mode, press "Turbo" button for a long time, remote controller enters into user individuation sleep
setting status, at this time, the time of remote controller will display "1hour", the setting temperature "88" will display
the corresponding temp- erature of last setting sleep curve and blink (The first entering will display according to
the initial curve setting value of original factory);
(2)Adjust "▲" and "
" button, could change the corresponding setting temperature, after adjusted, press "Turbo" button
for confirmation;
(3) At this time, 1hour will be automatically increased at the timer postion on the remote
or "8hours"), the place of setting temperature "88" will display the corresponding temperature of last setting sleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8 hours temperature setting finished, sleep,curve setting finished, at this time,
the remote controller will resume the original timer display; temperature display will resume to original setting temperature.
Technical Information
no display
(stops at current position)
no display
", air conditioner is blowing fan at fixed position. Horizontal louver will stop at the fixed
", air conditioner is blowing fan at fixed angle. Horizontal louver will send air at the fixed angle.
.
this button again within 2s, the change of swing status will also depend on the
), Sleep 2 (
Sleep 1 is Sleep mode 1, in Cool modes; sleep status
.
, if
press this button again 2s later,
, if press this button again 2s later,
), Sleep 3 (
) and cancel the Sleep, circulate between these,
after run for one hour, the
, then the unit will run at this
control, (that are "2hours" or "3hours"
15

Advertisement

Table of Contents
loading

Table of Contents