Operation Manual / 4 Product description / A130-M.. - A145-M..
6
Periodic maintenance work
Heating up the fluid
To shorten the soaking time, the fluid can be heated up to a maximum of
60 ºC.
NOTICE
Heating up of cleaning agents and operating fluids
When cleaning agents or operating fluids are heated up, explosive vapours
can be produced which are hazardous to health.
WARNING
Observe the information in the material safety data sheet.
Wear a respiratory mask according to material safety data sheet.
Water and dirt in the cartridge group
If water or dirt enters the cartridge group, this can impair the function of the
turbocharger and damage parts inside the cartridge group.
CAUTION
Place the cartridge group on suitable supports (01) made of wood or
metal.
Observe value (B) for the supports (01) so that the cartridge group is not
immersed too deeply.
Let the layers of dirt on the turbine soak for four hours.
Removing dirt
Health hazard due to soot particles
If soot particles enter the eyes or respiratory tract, this can be harmful to
health.
WARNING
Avoid the formation of dust.
Vacuum up dust with a suitable vacuum cleaner.
Wear a respiratory mask to protect against particles (P1 or P2 mask).
Wear safety goggles.
Wear safety goggles.
Wear a respiratory mask to protect against particles.
Wear safety gloves against mechanical risks.
Lift up the cartridge group and align it horizontally.
Remove dirt manually using a soft brush or a wire brush.