1.4. Error display

See the table below for descriptions of the displayed errors and countermeasures for these.
If multiple errors occur, only one item is displayed.
The priority order is w, e, r, t, y, q.
Condition
States
The model name, brand name and region information
written in the firmware are compared to the region
settings in the PCB. This error is displayed if the infor-
q
Firm Check
mation does not match.
NG
( # : 1/2/3/4)
" ▲ " is displayed as the first character if the firmware
is not correct (see the illustrations on the right).
An error occurs in Loop back Test of the DDR memory
which is performed during the initial setting of i/p
Scaler(ADV8003).
w
IP SCALER NG
During the initial setting of i/p Scaler ( ADV8003 ) ,
there is not the reply of the Loop back Test result of
the DDR memory .
If the Main CPU version is not supported by the GUI
e
Serial Flash (ADV8003),
GUI Serial
" ▼ " is displayed as the first character of the GUI
Flash NG
firmware version.
This error is displayed if there is no response from the
r
DIR NG
DIR.
The DSP FLAG0 port does not enter "Hi" status while
booting a DSP code even after resetting DSP.
The DSP FLAG0 port does not enter "Hi" status before
issuing a DSP command.
Setting WRITE to "Lo" does not set ACK to "Hi" during
t
DSP data reading.
DSP NG
Setting REQ to "Lo" does not set ACK to "Lo" during
( # : 1/2/3/4)
DSP data reading.
Setting WRITE to "Hi" does not set ACK to "Hi" during
DSP data writing.
Setting REQ to "Lo" does not set ACK to "Lo" during
DSP data writing.
An error occurred in a checksum of the EEPROM(*** is
y
EEPROM NG
a block address number).
Display
FIRM ERROR
Main
:**:**
Main FBL :**.**
DSP#
:**.**
Audio PLD:**.**
Video PLD:**.**
GUI
:********
IP SCALER ERR 01
IP SCALER ERR 02
GUI VER. ERROR
GUI
:********
DIR ERROR 01
DSP# ERROR 01
DSP# ERROR 02
DSP# ERROR 03
DSP# ERROR 04
DSP# ERROR 05
DSP# ERROR 06
BACKUP ERROR
131
TROUBLE SHOOTING
• Check the resistor for setting the
region(R1590 / R1589, DIGITAL PCB).
• Write the firmware for the correct
region.
• Check the circuits around the IP
SCALER (IC401, DIGITAL PCB) and
DDR2 (IC402/IC403).
If there appear to be no problems,
IC401 or IC402/IC403 is faulty.
• Check the firmware version.
• Check the DIR (IC202, DIGITAL PCB)
and surrounding circuits.
• Check the DSP (IC251/IC261/IC271/
IC281, DIGITAL PCB) and surrounding
circuits.