Marantz AV7703 Service Manual page 118

Av pre tuner
Hide thumbs Also See for AV7703:
Table of Contents

Advertisement

When the results of check item (52) are "00"
(Detection of HPD is not OK / Detection of RXSENSE is not OK )
Checking the HPD/RXSENSE status register. (Monitor2)
Check item(58).
Checking the HPD and RXSENSE. :
Does the test point of RXSENSE close to the HDMI output terminal
(JK432) indicate the (3.3V)?
Does the voltage of HPD test point close to the HDMI output terminal
(JK432) indicate "Hi" (3-5 V)?
JK432
HPD
YES
NO
Check for a short circuit in the TMDS/ HPD line.
If there is no problem, the HDMI Tx (IC431) is faulty.
Replace with a new device.
HDMI Tx (IC431) is faulty.
Replace with a new device.
Recheck from
check item (5).
If it does not work, replace the PCB.