Marantz NR1506 /U1B Service Manual page 62

Table of Contents

Advertisement

Error
DPMS Update Error Display
Code
5B
U p d a t i n g
5C
U p d a t i n g
5D
U p d a t i n g
5E
U p d a t i n g
5F
U p d a t i n g
60
U p d a t i n g
61
U p d a t e C h e c k N G
62
U p d a t i n g
80
U p d a t i n g
81
U p d a t i n g
82
U p d a t i n g
83
U p d a t i n g
84
U p d a t i n g
85
U p d a t i n g
86
U p d a t i n g
A0
C o n n e c t i o n F a i l A 0
NACK received in response or
no response from Sub for the "L"
f a i l
5 B
command.
No Update Packet received from
f a i l
5 C
CY920 (Time Out).
Abnormal data in Update Packet
f a i l
5 D
received from CY920 (CRCError).
Abnormal data in Update Packet
received from CY920 (PacketNo-
f a i l
5 E
Error).
Setup failure of the XModem
f a i l
5 F
transfer method.
NACK received in response or
no response from Sub for the "P"
f a i l
6 0
command.
Mismatched Check Sum in re-
sponse or no response from Sub
6 1
for the "I" command.
Failed to start up Sub in Power On
f a i l
6 2
sequence during Update.
Write Enable Latch Bit not set in
Read after issuing the "WREN"
f a i l
8 0
command.
Block Erase failed in Read after
f a i l
8 1
issuing the "BE" command.
No Update Packet received from
f a i l
8 2
CY920 (Time Out).
Abnormal data in Update Packet
f a i l
8 3
received from CY920 (CRCError).
Abnormal data in Update Packet
received from CY920 (PacketNo-
f a i l
8 4
Error).
Setup failure of the XModem
f a i l
8 5
transfer method.
Mismatched Check Sum in Check
f a i l
8 6
Sum comparison after rewriting.
IP Address acquisition failure
(AutoIP).
62
Details of Error code
Remedies
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Turn off and on the power. Updating
starts automatically.
Check the network connection. Carry
out the update in an environment that
has little network load.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nr1506 /n1bNr1506 /n1sgNr1506 /k1b

Table of Contents