Download Print this page

Outdoor Fan / Fan Motor - Daikin 2MKC30QVM4 Service Manual

Removal procedure

Advertisement

Si121656E

2. Outdoor Fan / Fan Motor

Warning
Step
1
Disconnect the
connector [S71] and
pull out the clamp.
2
Release the fan motor
lead wire from the
groove.
3
Remove the nut, and
then the outdoor fan.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Groove
Fan motor lead wire
Nut
D-cut
Outdoor fan
[S71]: fan motor
[S71]
When reassembling, fix the
shield plate to the electrical
box using the clamp.
Clamp
(R23602)
When reassembling, put the
fan motor lead wire through
the back of the fan motor to
avoid any entanglement with
the outdoor fan.
Lead wire
(R23604)
Nut size: M6
When reassembling, align
the
fan with the D-cut section of
the motor shaft.
Outdoor Fan / Fan Motor
Points
Clamp
(R23603)
Outdoor fan
(R3249)
10 mm
(0.39 inch)
(R18954)
mark of the outdoor
3

Advertisement

loading