Error Display - Samsung AG042KSV Series Installation Manual

Dvm chiller
Table of Contents

Advertisement

Error display

f Segment will display error code (4 digit).
HYDRO-UNIT_MODULE_CHILLER
Display
Communication error between hydro
controller and inverter controller
101
(If not received for 3 minutes from outdoor
unit)
108
Error due to repeated setting address
Communication error of hydro controller
109
address not complete
122
Error on hydro Evap in Sensor (Open/Short)
Error on hydro Evap out Sensor (Open/
123
Short)
128
Error on hydro Evap in Sensor (Detached)
129
Error on hydro Evap out sensor (Detached)
144
Error on hydro pipe temperature 2 sensor
145
Error on hydro EVA OUT 2 sensor
151
Hydro EEV open error (2nd detection)
Error due to closed EEV of hydro (2nd
152
detection)
Error on hydro floating switch (2nd
153
detection)
162
Inverter controller EEPROM error
Hydro controller EEPROM option setting
163
error
Error due to disconnected thermal fuse
198
(Temperature of terminal block increases.)
Communication error between hydro
201
controller and inverter controller
DB68-05916A-09_IM_DVM Chiller Outdoor_EU_EN_.indd 77
88-SEG DISPLAY
K1
K2
K3
K4
K5
K6
Description
Display
Description
Communication error between hydro
controller and inverter controller (When
202
there is no response from indoor units after
tracking is completed)
Communication error of Main and sub
203
MICOM of inverter controller
Communication error of inverter
205
controller main PBA - sub PBA (Sub PBA
communication all not received)
Communication error of inverter
controller main PBA - sub PBA (Sub PBA
communication partially not received)
Specification of PBA display for actual
206
communication error
C001: Hub PCB communication error
C002: Fan PCB communication error
C003: INV1 communication error
C004: INV2 communication error
Error on outdoor temperature sensor (Short
221
or Open)
231
Error on COND outlet sensor (Short or Open)
241
COND outlet sensor is detached
Error on discharge temperature of COMP1
251
(Short or Open)
Error on discharge temperature of COMP2
257
(Short or Open)
Discharge temperature sensor of COMP1 is
262
detached
Discharge temperature sensor of COMP2 is
263
detached
266
Top1 temperature sensor is detached
267
Top2 temperature sensor is detached
269
Suction temperature sensor is detached
270
Suction 2 temperature sensor is detached
Error on Top 1 temperature sensor (Short or
276
Open)
77
English
2022-05-02 오전 9:00:15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag056ksv seriesAg070ksv series

Table of Contents