8. Level 3 Repair
8-4-15. MST
MST is not working
Check MST function ON
Check the Antenna contact
ANT8002, ANT8004
Check the battery level
Battery >= 5%
Type *#0*# -> MST Test On
Check voltage on C8129
Check the Status of U8025
Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
END
No
Enable MST Function.
1. Resolder or Replace
No
ANT8002, ANT8004
2. Replace REAR
No
Charging the Battery
No
Resolder or Replace U8025
No
Resolder or Replace U8025