11.
A REF
– Set the reference (minimum) scaled frequency value for the analogue output.
[Default 0]
Enter the displayed (scaled) value, below which the analogue output will be at the
minimum for the selected voltage/current range.
Press select
←
to select digit and increment
In signed mode, after cycling through all six digits, all digits will flash and the sign can
be toggled by pressing increment ↑.
The number of decimal places is limited by the DISP DP setting.
Press settings
12.
A FULL
– Set the full scale (maximum) value for the analogue output. [Default 0]
Enter the displayed (scaled) value, above which the analogue output will be at the
maximum for the selected voltage/current range.
Press select
←
to select digit and increment
In signed mode, after cycling through all six digits, all digits will flash and the sign can
be toggled by pressing increment ↑.
The number of decimal places is limited by the DISP DP setting.
Press settings
13.
D OUT
– Set the digital frequency divider factor. [Default 0]
This can be set anywhere between 0 (digital output off) and 1 (digital output
frequency equal to the input frequency). Values greater than 1 will be set to 1
automatically.
Press select
←
to select digit and increment
After cycling through all digits the decimal point position can be altered by pressing
increment ↑.
Press settings
14.
WAIT
– Set the wait time in seconds [Default 1]
Set the wait time in seconds that the unit will wait to receive a pulse on the active
input(s) before displaying zero (or the offset value if this has been set).
This setting can be anywhere between 0 and 20.
Press increment
Press settings
at any time to move to the next setting.
at any time to move to the next setting.
at any time to move to the next setting.
↑
to change value.
or select
←
to move to the next setting.
↑
to change value.
↑
to change value.
↑
to change value.
14