16

Transport, storage and disposal

The sensor must be protected from damaging environmental factors and mechanical damage
during transport with the use of adequate packing.
The sensor may not be stored in ambient temperatures outside the permitted operating
temperature.
The product contains electronic components and must be disposed of properly in accordance
with local laws and regulations.
17

Coding HE050

HE series
050 = IO link sensor
Certifications
0 = CE / IEC / cULus / EAC
1 = CE / IEC / cULus / EAC + SIL 1
IO link
0 = Configuration only ex works: Transmitter / switching contacts
1 = IO link (output 1): Transmitter / switching contacts
Housing
0 = 1.4305 (V2A) with fastening M8 x 8 mm; incline 1.25 (Standard)
1 = 1.4404 (V4A) with fastening M8 x 8 mm; incline 1.25 mm
2 = 1.4462 duplex stainless steel with fastening M8 x 8 mm; incline 1.25 mm
Software parameter settings (factory default)
001 =
002 =
003 =
004 =
005 =
006 =
Output 1
Output 2
-
-
-
4-20 mA ~ 0-16 mm/s, rms; 10 Hz-1000 Hz
-
4-20 mA ~ 0-25 mm/s, rms; 10 Hz-1000 Hz
-
4-20 mA ~ 0-32 mm/s, rms; 10 Hz-1000 Hz
-
4-20 mA ~ 0-50 mm/s, rms; 10 Hz-1000 Hz
-
4-20 mA ~ 0-64 mm/s, rms; 10 Hz-1000 Hz