INSTALLER

4400BF Fountains are among the easiest to install Fountains on the market today. To
assure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES. After installation, leave these instructions with the
Fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC-
TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
4400BF FOUNTAIN
Owners Manual
Model 4400BF
IMPORTANT
IMPORTANT! INSTALLER PLEASE NOTE.
PAGE 1
98641C (Rev. A - 11/10)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 4400BF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Halsey Taylor 4400BF

  • Page 1 Model 4400BF Floor Mount Tubular Bottle Filler Fountain INSTALLER 4400BF Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
  • Page 2 4400BF FOUNTAIN 98641C (Rev. A - 11/10) PAGE 2...
  • Page 3 4400BF FOUNTAIN 1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be capable of supporting 300 lb. load on fountain. 2. Refer to rough-in for plumbing. 3. Install shut-off valve on water supply. (Valve not furnished) 4.
  • Page 4 4400BF FOUNTAIN ITEMIZED PARTS LIST ITEM NO. PART NO. DESCRIPTION Cover - Round Plate 28955C 6 & 15 Drain Plug 1-1/2" 45464C Access Panel 45832C In - Line Strainer 55996C Tube - Drain 66815C Kit - "O" Rings and Fittings...

Table of Contents