Marantz SR5012 Service Manual page 101

Av surround receiver
Hide thumbs Also See for SR5012:
Table of Contents

Advertisement

3-2. Error Code H1-02 failure detection procedure
Checking device.
[U1000 :
MN864788]
Check the power supply voltage. (HDMI Rx)
Check item(11).
Check the power supply voltage. :
Does the power supply voltage of the HDMI Rx1 [U1000] indicate the correct voltage (1.1V, 3.3V)?
The test points are as follows.
HDMI Rx1
112 pin
U1000
38 pin
1.1V
3.3V
YES
Check item(12).
Check the power components [U1063/U1066] and the pattern on
the substrate.
If there is no problem, remove the HDMI Rx [U1000] from the sub-
strate and measure the voltage at the test point of
Is the voltage correct (1.1V or 3.3V)?
Replace with a new device.
Recheck from
If it does not work, replace the PCB.
NO
Check the power supply voltage. :
check item
YES
NO
The power supply circuit is
faulty.
Replace the PCB.
check item (1).
Checking the reset waveform. (HDMI Rx)
Check item(13).
Checking the reset waveform :
Check the waveform.
Is the "RESET" waveform of the TP near the HDMI Rx [U1000]
correct (like the one shown in the diagram) when the power is
turned on?
HDMI Rx1
RESET
U1000
YES
(11).
101
Examples of confirmation waveform
Voltage scale : 1.0V/div
Time scale : 20ms/div
NO
Check the reset circuit between
CPU [U1018] and HDMI Rx
[U1000].
If there is no problem, the HDMI
Rx [U1000] is faulty.
Replace with a new device.
Recheck from
check item (1).
If it does not work, replace the
PCB.
Go to next page.