30" FULL GAS RANGE INSTALLATION INSTRUCTIONS
Electrical shock hazard
WARNING
• For personal safety, this
• It is the personal responsi-
This range is equipped with a factory-connected
power cord. The cord must be connected to a
grounded 120 volt - 60 Hz outlet. If no outlet is avail-
able, have one installed by a qualified electrician.
CAUTION
Do not use multiple outlets, exten-
sion cords or adapters.
See the rating plate for technical specifications. The
rating plate is visibly located on the right side of the
oven door frame.
appliance must be properly
grounded. For maximum
safety, the power cord must
be securely connected to an
electrical outlet or junction
box that is the correct volt-
age, is correctly polarized
and properly grounded, and
protected by a circuit
breaker in accordance with
local codes.
bility of the consumer to
have the appropriate outlet
or junction box with the cor-
rect, properly grounded wall
receptacle installed by a
qualified electrician. It is the
responsibility and obligation
of the consumer to contact a
qualified installer to ensure
that the electrical installation
is suitable and in confor-
mance with all local codes
and ordinances.
This ID plate must never be removed.
Gas safety
WARNING
Burning gas cooking fuel gener-
ates some by-products which are on the list of sub-
stances which are known by the State of California
to cause cancer or reproductive harm. To minimize
exposure to these substances, always operate this
unit according to the instructions contained in this
booklet and provide good ventilation.
Install a gas shutoff valve near the appliance. It must
be easily accessible in an emergency.
Leak testing must be conducted by the installer
according to the instructions in this manual. The
appliance and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing at pressures in excess
of ½ psi (3.5 kPa).
The appliance must be isolated from the gas supply
piping system by turning off its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than ½ psi (3.5 kPa). The minimum supply pres-
sure must be 1" water column above the manifold
pressure printed on the rating label. The maximum
supply pressure of 14.0 inches water column (34.9
Millibars) must not exceed.