2.Specifications

NOMINAL DISTRIBUTION SYSTEM VOLTAGE
Phase
Frequency
Voltage
NOMINAL CAPACITY and NOMINAL INPUT
Capacity rated
Power Consumption(Rated)
SEER/SCOP
Annual energy consumption
Moisture Removal
TECHNICAL SPECIFICATIONS-UNIT
Dimensions
H*W*D
Packaged
H*W*D
Dimensions
Net Weight
Gross weight
/
Sound pressure
Sound level
Sound power
ELECTRICAL SPECIFICATIONS
Nominal running current
Maximum running current
Starting current
TECHNICAL SPECIFICATIONS-PARTS
Type
Model
Compressor
Motor output
Oil type
Oil charge volume
Type
Motor output
Fan
Air flow rate(high)
Speed(high/low)
Heat
Type
/
Hz
V
kW
Btu/h
kW
W/W
kWh
m³/h
mm
mm
KG
KG
dB
dB
A
A
A
W
L
W
m³/h
rpm
1
50
220-240
Cooling
3.50
11940
0.87
8.5/A+++
144
1.6*10
﹣³
800×275×553
908×405×625
30
32.9
48
61
Cooling
3.9
6.7
1
cooling
Rotary Compressor
GSD098RKTF6JV6B
695
ASC-68R or equivalent
0.280±0.0±2
Axial fan
40
1900
850/300
ML fin-φ7HI-HX tube
7
Specification
heating
4.20
14330
1.1
4.6/A++
854
heating
5.0
7.2
1
heating
Domestic air conditioner