Haier 1U35S2SM1FA-2 Service Manual page 50

Wall mounted type
Hide thumbs Also See for 1U35S2SM1FA-2:
Table of Contents

Advertisement

11.4 Cooling suction pressure curves
outdoor temp.
(humidity 46%)
DB/WB
-20℃
-10℃
0℃
8℃
15℃
20℃
25℃
30℃
35℃
38℃
40℃
43℃
1350
1250
1150
1050
950
850
750
650
550
450
350
-20℃ -10℃0℃ 8℃ 15℃20℃25℃30℃35℃38℃40℃43℃
performance curves
cooling suction pressure.table
21/15℃
569
599
624
644
657
663
698
735
774
815
896
986
cooling suction pressure and temp.curves
outdoor temp.(DB/WB)
Performance and ceves diagrams
indoor temp.
27/19℃
702
738
769
793
809
817
826
869
878
905
996
1075
52
35/24℃
807
849
885
912
931
940
959
969
1020
1041
1145
1248
21/15℃
27/19℃
35/24℃
Domestic air conditioner