EAS Electric ECRL120P Operating Manual

EAS Electric ECRL120P Operating Manual

Wired controller
Table of Contents
  • Table of Contents
  • Mesure de Sécurité
  • Installation Accessoire
  • 70 Méthode D'installation
  • Spécification
  • Fonction de la Commande Filaire
  • Instructions de Fonctionnement
  • Fonctionnement
  • Fonctions de Minuterie
  • Minuterie Hebdomadaire
  • Gestion de L'alarme D'erreur
  • Indications Techniques Et Exigences

Advertisement

Available languages

Available languages

Quick Links

MANDO POR CABLE
WIRED CONTROLLER
COMMANDE FILAIRE
ECRL120P
MANUAL DE INSTRUCCIONES
OPERATING MANUAL
MANUEL D'INSTRUCTIONS
V.2

Advertisement

Table of Contents
loading

Summary of Contents for EAS Electric ECRL120P

  • Page 1 MANDO POR CABLE WIRED CONTROLLER COMMANDE FILAIRE ECRL120P MANUAL DE INSTRUCCIONES OPERATING MANUAL MANUEL D'INSTRUCTIONS...
  • Page 2 INSTRUCCIONES DE SEGURIDAD Contenido ACCESORIOS DE INSTALACIÓN MÉTODO DE INSTALACIÓN ESPECIFICACIONES FUNCIONES Y CARACTERÍSTICAS PANTALLA DEL MANDO BOTONES DEL MANDO PREPARATIVOS PREVIOS AL USO USO DEL MANDO FUNCIONES DEL TEMPORIZADOR Programación semanal CÓDIGOS DE ERROR INDICADORES Y REQUISITOS TÉCNICOS Este manual detalla todas las instrucciones que deben tenerse en cuenta para el uso del aparato.
  • Page 3 1. INSTRUCCIONES DE SEGURIDAD  Lea atentamente las precauciones antes de instalar la unidad.  Las siguientes instrucciones se refieren a normas de seguri- dad importantes que deben seguirse. Indica que un uso inadecuado puede provocar la ADVERTENCIA muerte o lesiones graves. Indica que un uso inadecuado puede provocar ATENCIÓN lesiones y daños a la propiedad.
  • Page 4 2. ACCESORIOS PARA LA INSTALACIÓN Elija la ubicación de instalación No debe instalarse donde haya aceites, vapores o gases sulfurosos, o el producto podría deformarse y provocar una avería del sistema. Preparación antes de la instalación 1. Confirme que dispone de todas las partes siguientes: Qty.
  • Page 5 2. ACCESORIOS PARA LA INSTALACIÓN Precaución en la instalación del control cableado 1. Este manual indica el método de instalación del mando por cable. Consulte el diagrama de cableado del manual de instalación si tiene dudas para conectar el cable del mando a la unidad interior.
  • Page 6 3. MÉTODO DE INSTALACIÓN 1. Imagen de tamaño de la estructura del control cableado 18.5 Fig 3-1 2. Diagrama del cableado eléctrico: Terminal CN40 Aplicable solo a de la placa ECRL120P/B ----------------------------------- rojo rojo ----------------------------------- negro negro ----------------------------------- amarillo amarillo ----------------------------------- marrón...
  • Page 7 3. MÉTODO DE INSTALACIÓN 3.Diagrama de conexión Cable apantallado Cable de conexión 1 Placa de 4 núcleos CN40 Cable de conexión 2 Conecte el terminal hembra del latiguillo conectado a la placa al terminal macho del cable de conexión. (Ver Fig.3-3) Conecte el otro extremo de los cables de conexión al terminal macho del cable apantallado del mando por cable.
  • Page 8 3.MÉTODO DE INSTALACIÓN 5. Asegure la placa posterior del control cableado Para montaje de superficie, fíjela a la pared con tres tornillos (M4x20) y tacos. (Fig.3-5) Placa posterior Tornillos (M4×20) Fig 3-5 Para el montaje en switch box, fije la parte trasera del switch box con 2 tornillos (M4x25) y móntelo en la pared con 1 tornillo (M4x20).
  • Page 9 3. MÉTODO DE INSTALACIÓN 6. Instalación de la pila Fig 3-7  Coloque la pila en la unidad y compruebe que el lado positivo se coloque según la marca de polaridad. (Véase Fig.3-7) Ajuste la hora correcta antes de usar el aparato. Las ...
  • Page 10 3. MÉTODO DE INSTALACIÓN 7. Cableado Salida de A. Para el cableado en las ranuras, hay cuatro cable lateral posiciones de salida. Hay tres necesidades de corte. superior Ranura de línea Salida del Salida de cable cable lateral lateral derecho izquierdo Ranura de Ranura...
  • Page 11 3. MÉTODO DE INSTALACIÓN 8.Vuelva a colocar la parte superior del mando. Al ajustar y montar la placa superior, evite pellizcar el cable. ( Fig 3-11 ) Fig 3-11 IMPORTANTE: Todas las fotos de este manual tienen sólo fines ilustrativos. Su modelo puede diferir ligeramente.
  • Page 12 4. ESPECIFICACIONES DC 5V/DC 12V Voltaje de entrada Temperatura ambiente -5~43℃(23~110 ℉) RH40%~RH90% Humedad ambiente...
  • Page 13 5.CARACTERÍSTICAS Y FUNCIONES DEL MANDO POR CABLE Características: Pantalla LCD POWER Visualización de códigos de error: útil para facilitar la reparación y servicio. 4 opciones de salida de cables, sin salientes en la parte posterior, facilitando la colocación de los cables y la instalación del dispositivo.
  • Page 14 6. DISPLAY DEL MANDO POR CABLE 8. Temperatura 1. Indicador de modo de funcionamiento 9. Indicador de bloqueo 2. Indicador de velocidad de ventilador 10. Indicador de temperatura 3. Indicador swing horizontal de la estancia 4. Indicador swing vertical 11. Reloj 5.
  • Page 15 7. BOTONES DEL MANDO POR CABLE POWER MODE FAN SPEED TIMER SWING SWING FOLLOW ME DELAY/DAY OFF CONFIRM BACK COPY...
  • Page 16 7. BOTONES DEL MANDO POR CABLE 1 Botón POWER (para encender) 2 Botón MODE (modo) 3 Botón Adjust (ajustes) 4 Botón FAN SPEED (velocidad del ventilador) 5 Botón UP-DOWN (dirección del aire y botón swing vertical) 6 Botón LEFT-RIGHT (botón swing horizontal) 7 Botón FOLLOW ME (seguimiento temperatura del mando) 8 Botón TIMER (temporizador) 9 Botón DELAY/DAY OFF (retrasar/ suprimir por hoy)
  • Page 17 8. PREPARATIVOS PARA EL FUNCIONAMIENTO Ajustes del día y del temporizador Presione el botón TIMER por 3 segundos o más. La pantalla del temporizador parpadeará. TIMER Presione el botón "+" o "-" para establecer la fecha. La fecha seleccionada parpadeará. Confirme la configuración pulsando TIMER o esperando 10 segundos para pasar a la configuración de la hora.
  • Page 18 9. FUNCIONAMIENTO Función de recepción de señal remota (según modelo) El mando por cable puede funcionar como dispositivo de recepción de señal remota, puede usar el mando a distancia inalámbrico para controlar el aire acondicionado a través del mando por cable cuando el sistema se haya encendido.
  • Page 19 9.FUNCIONAMIENTO Ajuste de velocidad del ventilador Presione el botón VELOCIDAD DEL VENTILADOR para configurar la velocidad del ventilador. (Este botón no está disponible cuando está en modo Auto o Seco) VELOCIDAD DEL VENTILADOR Selección del sensor de temperatura ambiente Unidad interior FOLLOW ME Pulse FOLLOW ME para seleccionar si...
  • Page 20 9.FUNCIONAMIENTO Función de bloqueo infantil Presione el botón "+" y "-" simultáneamente durante 3 segundos para activar la función de bloqueo para niños y bloquea todos los botones en el mando por cable. Presione los botones nuevamente durante 3 segundos para desactivar la función de bloqueo para niños.
  • Page 21 9. FUNCIONAMIENTO Función de elevación de panel (sólo para algunos modelos de cassette) Cuando la unidad esté apagada, presione el botón MODE durante un tiempo para activar la función de elevación de panel. Aparecerá parpadeando el símbolo MODE Cuando se ajusta el panel aparece el código F2.
  • Page 22 9.FUNCIONAMIENTO Función Swing Dirección y oscilación vertical del flujo de aire Use el botón SWING para ajustar la dirección vertical del flujo de aire. SWING SWING 1. Cada vez que el usuario pulsa SWING, la lama se desplaza 6 grados. 2.
  • Page 23 10. FUNCIONES DELTEMPORIZADOR Temporizador semanal Se usa para configurar las horas de funcionamiento para cada día de la semana. Temporizador de encendido Para iniciar el funcionamiento del aire acondicionado. Cuando se configura el temporizador el aire acondicionado se pone en marcha al alcanzar esa hora.
  • Page 24 10. FUNCIONES DEL TEMPORIZADOR Para configurar el temporizador de encendido o apagado Presione el botón TIMER para seleccionar No se TIMER muestra nada Pulse Confirm y el reloj parpadeará. CONFIRM ej. Temporizador de apagado configurado para las 18:00. Pulse + o − para ajustar la hora. Una vez configu- rado, el temporizador pone en marcha o apaga la máquina automáticamente.
  • Page 25 10. FUNCIONES DEL TEMPORIZADOR Para configurar el temporizador de encendido y apagado Pulse Timer hasta seleccionar TIMER Pulse Confirm y el reloj parpadeará. CONFIRM CONFIRM Pulse + o - para configurar la hora de encendido y luego pulse Confirm. Pulse + o - para configurar la hora de apagado.
  • Page 26 11.TEMPORIZADOR SEMANAL Ajuste de temporizador semanal TIMER CONFIRM Presione el botón TIMER para seleccionar y luego presione el botón CONFIRMAR. Ajuste del día de la semana CONFIRM Presione el botón "+" o "-" para seleccionar el día de la semana y luego presione el botón CONFIRMAR para confirmar la configuración Ajuste 1 del temporizador de encendido CONFIRM...
  • Page 27 11.TEMPORIZADOR SEMANAL ej. Programación de encendido 1 para los martes Se pueden guardar hasta 4 configuraciones de temporizador para cada día de la semana, lo que facilita que el usuario ajuste la programación a su estilo de vida. Ajuste 1 del temporizador de apagado CONFIRM Pulse + y −...
  • Page 28 11. TEMPORIZADOR SEMANAL Funcionamiento del TEMPORIZADOR SEMANAL Para activar el TEMPORIZADOR SEMANAL ● Presione el botón TIMER mientras se muestra en la pantalla LCD. TIMER ● Para desactivar el TEMPORIZADOR SEMANAL desaparezca de la pantalla LCD. Presione el botón TIMER hasta que TIMER ●...
  • Page 29 11. TEMPORIZADOR SEMANAL Para configurar DAY OFF (para anular sólo un día de la programación) Tras configurar la programación semanal, pulse CONFIRM. CONFIRM Pulse + o − para seleccionar el día de la semana. Pulse DAY OFF para anular uno de los días. La marca está...
  • Page 30 11. TEMPORIZADOR SEMANAL Función DELAY Con el temporizador semanal en marcha, al presionar el botón DELAY una vez, aparece " ". Presione este botón dos veces y se mostrará " " . Espere 3 segundos para confirmar. Significa que la unidad retrasará la programación 1 hora; DELAY/ Presione este botón tres veces y se mostrará...
  • Page 31 11.TEMPORIZADOR SEMANAL Pulse COPY (se mostrarán las letras CY en la pantalla). CO PY Pulse + o − para seleccionar el día al que desea copiar la selección. Pulse COPY para confirmar. CO PY El icono parpadea rápidamente ej. Copia de los ajustes del lunes al miércoles Se pueden copiar otros días repitiendo los pasos 4 y 5.
  • Page 32 14. SOLUCIÓN DE PROBLEMAS Si el sistema no funciona correctamente o si los casos mencionados a continuación son evidentes, inspeccione el sistema según estos pasos: CÓDIGO DEFINICIÓN DEL ERROR O PROTECCIÓN MOSTRADO Error de comunicación entre el mando por cable y la unidad interior El panel de autoelevación no funciona correctamente Compruebe el error mostrado en la placa display de la unidad interior y...
  • Page 33 SAFETY PRECAUTION Contents INSTALLATION ACCESSORY INSTALLATION METHOD SPECIFICATION FEATURES AND FUNCTIONS DISPLAY BUTTONS PREPARATORY OPERATION OPERATION TIMER FUNCTIONS Weekly timer FAULT ALARM TECHNICAL INDICATION AND REQUIREMENT This manual gives detailed description of the precautions that should be brought to your attention during operation. To ensure the correct service of the wired controller, read this manual carefully before using the unit.
  • Page 34 1. SAFETY PRECAUTION  Read the safety precautions carefully before installing the unit.  Stated below are important safety issues that must be obeyed. Means improper handling may lead to personal death or WARNING severe injury. Means improper handling may lead to personal injury or CAUTION property loss.
  • Page 35 2. INSTALLATION ACCESSORY Select the installation location Don’t install at the place where cover with heavy oil, vapor or sulfureted gas, otherwise, this product would be deformed that would lead to system malfunction. Preparation before installation 1. Please confirm that all the following parts you have been supply. Qty.
  • Page 36 2. INSTALLATION ACCESSORY Precaution of install the wire controller 1. This manual provides the installation method of wire controller. Please refer to the wiring diagram of this installation manual to wire the wire controller with indoor unit. 2. The wire controller working in low voltage loop circuit. Forbid to directly contact the cable of 220Vcommercial electricity or of 380V high voltage, and don’t wire this kind of wire in the said loop;...
  • Page 37 3. INSTALLATION METHOD 1.Wired remote controller structure size figure 18.5 Fig 3-1 2.Wiring Principle Sketch: Insert of the mainboard CN40 Applicable to ECRL120P/B only ----------------------------------- black ----------------------------------- black yellow yellow ----------------------------------- brown ----------------------------------- brown 4-Core Shield Cable, the length Indoor unit mainboard...
  • Page 38 3. INSTALLATION METHOD 3.Wiring figure Connective wires group-1 Mainboard 4-core shielding wire CN40 Connective wires group-2 Fig 3-3 Connect the female joint of wires group from the mainboard with the male joint of connective wires group. (See Fig.3-3) Please connect the other side of connective wires group with the male joint of wires group leads from wire controller.
  • Page 39 3. INSTALLATION METHOD 5. Fasten the back plate of the wire controller For exposed mounting, fasten the back plate on the wall with the 3 screws (M4×20) and plugs. (Fig.3-5) Back plate Screws (M4×20) Fig 3-5 For flush-mounting, fasten the back plate on the switch box with 2 screws (M4×25) and fasten it on the wall with 1 screw (M4×20).
  • Page 40 3. INSTALLATION METHOD 6. Battery installation Fig 3-7  Put the battery into the installation site and make sure the positive side of the battery is in accordance with the positive side of installation site.(See Fig.3-7)  Please set the time corrected on the first time operation. Batteries in the wired controller can maintain the correct time during a power failure.
  • Page 41 3. INSTALLATION METHOD 7. Wiring A. For wiring in the slot, four outletting positions. Top side There are three need cutting. wire outlet Line groove Right side Left side wire outlet wire outlet Line groove Line groove Cutting place of right Cutting place of left Cutting place of top Bottom side...
  • Page 42 3. INSTALLATION METHOD 8.Reattach the upper part of the wire controller After adjusting the upper case and then buckle the upper case; avoid clamping the wiring during installation. ( Fig 3-1 1) Fig 3-11 All the pictures in this manual are for explanation purpose only. Your wire controller may be slightly different .The actual shape shall prevail.
  • Page 43 4. SPECIFICATION DC 5V/DC 12V Input voltage -5~43℃(23~110℉) Ambient temperature RH40%~RH90% Ambient humidity...
  • Page 44 5. FEATURE AND FUNCTION OF THE WIRED CONTROLLER Feature: LCD display. Malfunction code display: it can POWER display the error code, helpful for service. 4-way wire layout design, no raised part at backside, more convenient to place the wires and install the device. Room temperature display.
  • Page 45 6. NAME ON THE LCD OF THE WIRE CONTROLLER 1 Operation mode indication 8 Temperature display 2 Fan speed indication 9 Lock indication 3 Left-right swing indication 10 Room temperature 4 Up-down swing indication indication 5 Faceplate function indication 11 Clock display 6 Follow me function indication 12 On/Off timer 7 C°...
  • Page 46 7. NAME OF THE BUTTON ON THE WIRE CONTROLLER POWER MODE FAN SPEED TIMER SWING SWING FOLLOW ME DELAY/DAY OFF CONFIRM BACK COPY...
  • Page 47 7. NAME OF THE BUTTON ON THE WIRE CONTROLLER 1 POWER button 2 MODE button 3 Adjust button 4 FAN SPEED button 5 UP-DOWN airflow direction and swing Button 6 LEFT-RIGHT swing Button 7 FOLLOW ME button 8 TIMER button 9 DELAY/DAY OFF button 10 CONFIRM button 11 BACK button...
  • Page 48 8. PREPARATORY OPERATION Set the current day and time Press the TIMER button for 3 seconds or more. The timer display will flash. TIMER Press the button “ + ” or “ - ” to set the date. The selected date will flash.
  • Page 49 9. OPERATION Remote signal receiving function The wired remote controller can be a remote signal receiving device, you can use the wireless remote controller to control the air-conditioner through the wired remote controller when the system have been powered on. To start/stop operation Press the POWER button.
  • Page 50 9. OPERATION Fan speed setting Press the FAN SPEED button to set the fan speed. (This button is unavailable when in the mode of Auto or Dry) FAN SPEED Room temperature sensor selection Indoor Unit FOLLOW ME Press the FOLLOW ME button to select whether room temperature...
  • Page 51 9. OPERATION Child lock function Press the button “+” and “-” simultaneously for 3 seconds to activate the child lock function and lock all buttons on the wire controller. Press the buttons again for 3 seconds to deactivate the child lock function.
  • Page 52 9. OPERATION Faceplate function (on some models) 1.When the unit is off, press the MODE button long to activate the faceplate function.The mark will flash. MODE The F2 mark appears when the faceplate is adjusted. 2. Press the button “+” and “-” to control the lift and drop of the faceplate.Pressing the “+”...
  • Page 53 9. OPERATION Up-Down airflow direction and swing (on some models) SWING SWING button to adjust the Up-down airflow direction. 1.Press the button every time, the louver swings 6 degrees. 2.Press and hold the button for 2 seconds,it turns into up-down swing mode, press it again to stop.
  • Page 54 10. TIMER FUNCTIONS WEEKLY timer Use this timer function to set operating times for each day of the week. On timer Use this timer function to start air conditioner operation. The timer operates and air conditioner operation starts after the time has passed.
  • Page 55 10. TIMER FUNCTIONS To set the On or Off TIMER Press the TIMER button to select the TIMER No display Press the CONFIRM button and the Clock display is flashing. CONFIRM ex.Off timer set at PM 6:00 Press the button “ + ” or “ - ” to set the time. After the time is set, the timer will start or stop automatically.
  • Page 56 10. TIMER FUNCTIONS To set the On and Off TIMER Press the TIMER button to select the TIMER Press the CONFIRM button and the Clock display is flashing. CONFIRM CONFIRM Press the button “ + ” or “ - ” to set the time of On timer,and then press the CONFIRM button to confirm the setting.
  • Page 57 11. WEEKLY TIMER Weekly timer setting TIMER CONFIRM Press the TIMER button to select the and then press the CONFIRM button to confirm. Day of the week setting CONFIRM Press the button “ + ” or “ - ” to select the day of the week and then press the CONFIRM button to confirm the setting.
  • Page 58 11. WEEKLY TIMER ex.Tuesday time scale 1 Up to 4 timer settings can be saved for each day of the week.It is conventent if the WEEKLY TIMER is set according to the user’s life style. Off timer setting of timer setting 1 CONFIRM Press the button “...
  • Page 59 11. WEEKLY TIMER WEEKLY timer operation ● To activate WEEKLY TIMER operation Press the TIMER button while is displayed on the LCD TIMER ● To deactivate WEEKLY TIMER operation Press the TIMER button while disappears from the LCD. TIMER ● To turn off the air conditioner during the weekly timer 1.
  • Page 60 11. WEEKLY TIMER To set the DAY OFF (for a holiday) During the weekly timer, press the CONFIRM button. CONFIRM Press the button “ + ” or “ - ” to select the day in this week. Press the DAY OFF button to set the DAY OFF. mark is hidden DELAY/DAY OFF ex.The DAY OFF is set for Wednesday...
  • Page 61 11. WEEKLY TIMER DELAY function During the weekly timer, pressing the DELAY button once, display " ". Press this button twice, display " " and wait 3 seconds to confirm. It means the unit will override 1 hours; Press this button three times,display " "...
  • Page 62 11. WEEKLY TIMER Press the COPY button,the letter “CY” will be shown on the LCD. COPY Press the button “ + ” or “ - ” to select the day to copy to. Press the COPY button to confirm . COPY mark flashes quickly ex.
  • Page 63 12. FAULT ALARM HANDING If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident, investigate the system according to the following procedures. D ISPLAY MALFUNCT ION & PROTECT ION DEFINE DIGITAL TU BE Error of communication between wire CONTROLLER and indoor unit The faceplate is abnormal...
  • Page 64: Table Of Contents

    MESURE DE SÉCURITÉ Contenu INSTALLATION ACCESSOIRE MÉTHODE D’INSTALLATION SPÉCIFICATION FONCTION DE LA COMMANDE FILAIRE ÉCRAN DE LA COMMANDE FILAIRE BOUTONS SUR LE CONTRÔLEUR INSTRUCTIONS DE FONCTIONNEMENT FONCTIONNEMENT FONCTIONS DE MINUTERIE MINUTERIE HEBDOMADAIRE GESTION DE L’ALARME D’ERREUR INDICATIONS TECHNIQUES ET EXIGENCES Ce manuel donne une description détaillée des précautions qui ...
  • Page 65: Mesure De Sécurité

    1.MESURE DE SÉCURITÉ  Lisez les consignes de sécurité avant d'installer l'appareil.  Indiqués ci-dessous sont importants problèmes de sécurité qui doivent être respectées. Signifie une mauvaise manipulation peut entraîner des ATTENTION décès ou des blessures graves. Moyens de manipulation incorrecte peut entraîner AVERTISSEMENT des blessures ou la perte de biens.
  • Page 66: Installation Accessoire

    2. INSTALLATION ACCESSOIRE Sélectionnez l'emplacement d'installation Ne pas installer à l'endroit où la couverture avec de l'huile lourde, vapeur ou gaz sulfureted, sinon, serait déformé ce produit qui conduirait à un mauvais fonctionnement du système. Préparation avant l'installation 1. S'il vous plaît confirmez que vous avez toutes les pièces suivantes: Qté.
  • Page 67 2. INSTALLATION ACCESSOIRE Précaution d'installer la commande filaire 1. Ce manuel fournit la méthode d'installation de la commande filaire. S'il vous plaît se référer au schéma de câblage de ce manuel d'installation pour raccorder la commande filaire avec l'unité intérieure. 2.
  • Page 68: 70 Méthode D'installation

    3. MÉTHODE D'INSTALLATION Image de la taille de la structure de la commande filaire 18.5 Fig 3-1 2.Schéma de câblage électrique: Insérer le CN40 Mainboard mainboard Applicable à ECRL120P/B ----------------------------------- rouge rouge ----------------------------------- noir noir jaune ----------------------------------- jaune ----------------------------------- marron marron Bouclier 4-Core câble, la longueur...
  • Page 69 3. MÉTHODE D'INSTALLATION 3. Figure de câblage Le groupe 1-fils conjonctifs mainboard fil de blindage 4-core CN40 Le groupe 2-fils conjonctifs Connecter le joint femelle du groupe de fils à partir du mainboard avec le joint mâle du groupe de fils conjonctif. (Voir Fig.3-3) S'il vous plaît connecter l'autre côté...
  • Page 70 3. MÉTHODE D'INSTALLATION 5. Fixer la plaque arrière du dispositif de la commande filaire Pour un montage exposé, fixer la plaque arrière sur le mur avec les 3 vis (M4 × 20) et des bouchons. (Fig.3-5) Plaque arrière Vis (M4 × 20) Fig 3-5 Pour montage encastré, fixer la plaque arrière sur le boîtier de commutateur avec 2 vis (M4 ×...
  • Page 71 3. MÉTHODE D'INSTALLATION 6. Installation de la batterie Fig 3-7  Mettez la batterie dans le installation site et assurez-vous que le côté positif de la batterie est conforme au côté positif de installation site. (Voir Fig.3-7)  Régler l'heure corrigée lors de la première opération. Les piles dans le contrôleur peuvent chronométrer en cas de panne de courant, garantissant ainsi que le temps passe bien.
  • Page 72 3. MÉTHODE D'INSTALLATION 7. Câblage Sortie de fil A. Pour le câblage dans la fente, quatre positions latéral supérieur de sortie. Il y a trois besoin de couper. Rainure de ligne Sortie de fil Sortie de fil latéral latéral droit gauche Rainure Rainure...
  • Page 73 3. MÉTHODE D'INSTALLATION 8. Remettre en place la partie supérieure du dispositif de la commande filaire Après avoir réglé le boîtier supérieur et boucle le boîtier supérieur; éviter le serrage de la câblage lors de l'installation. (Fig 3-11) Fig 3-11 Toutes les images de ce manuel sont à...
  • Page 74: Spécification

    4. SPÉCIFICATION DC 5V/DC 12V Tension d'entrée Température ambiante -5~43℃(23~110 ℉) RH40%~RH90% Humidité ambiante...
  • Page 75: Fonction De La Commande Filaire

    5. FONCTION DE LA COMMANDE FILAIRE Caractéristique: Écran LCD. Affichage du code de dysfonctionnement: POWER il peut afficher le code d'erreur, utile pour le service. Conception de disposition de fil à 4 voies, aucune partie surélevée à l'arrière, plus pratique pour placer les fils et installer l'appareil.
  • Page 76 6. NOM SUR L'ÉCRAN LCD DU CONTRÔLEUR FILAIRE 1 Indication du mode de 8 Affichage de la température fonctionnement 9 Indication de verrouillage 2 Ventilateur indication de la vitesse 10 Indication de la température 3 Indication de swing gauche-droite ambiante 4 Indication de swing en haut et en 11 Affichage de l'horloge 12 Minuterie On / Off...
  • Page 77 7. NOM DU BOUTON SUR LE CONTRÔLEUR DE FILAIRE POWER MODE FAN SPEED TIMER SWING SWING FOLLOW ME DELAY/DAY OFF CONFIRM BACK COPY...
  • Page 78 7. NOM DU BOUTON SUR LE CONTRÔLEUR DE FILAIRE 1 Bouton POWER 2 Bouton MODE 3 Bouton de réglage 4 Bouton de la VITESSE DU VENTILATEUR 5 Direction du flux d'air UP-DOWN et bouton SWING 6 Bouton SWING droit et gauche 7 FOLLOW ME 8 Bouton TIMER 9 Bouton DELAY / DAY OFF...
  • Page 79: Instructions De Fonctionnement

    8. INSTRUCTIONS DE FONCTIONNEMENT Réglez le jour et l'heure Appuyez sur la touche TIMER pendant 3 secondes ou plus.L'affichage de la minuterie clignotera. TIMER Appuyez sur le bouton « + » ou « - » pour régler la date. La sélection la date clignotera.
  • Page 80: Fonctionnement

    9. FONCTIONNEMENT Fonction de réception de signal à distance La commande filaire peut être un dispositif de réception de signal à distance, on peut utiliser le dispositif de commande à distance sans fil pour commander le climatiseur par l'intermédiaire de la commande filaire lorsque le système a été...
  • Page 81 9. FONCTIONNEMENT Réglage du ventilateur de la vitesse Appuyez sur le bouton FAN SPEED pour régler la vitesse du ventilateur. (Ce bouton est disponible en mode Auto ou sec) VITESSE DU VENTILATEUR Sélection du capteur de température ambiante Unité intérieure FOLLOW ME Appuyez sur le bouton FOLLOW ME pour sélectionner sila température ambiante est...
  • Page 82 9. FONCTIONNEMENT Fonction de verrouillage de l'enfant Appuyez sur le bouton « + » et « - » simultanément pendant 3 secondes pour activer la fonction de verrouillage de l'enfant pour verrouiller tous les boutons sur le contrôleur. Appuyez sur les boutons pendant 3 secondes pour désactiver la fonction de verrouillage de l'enfant.
  • Page 83 9. FONCTIONNEMENT Fonction Faceplate (sur certains modèles) 1. Lorsque l'appareil est éteint, appuyez sur le bouton MODE long pour activer la fonction. La marque clignote. MODE La marque F2 apparaît lorsque la faceplate est réglée. 2. Appuyez sur le bouton « + » et « - » pour contrôler l'ascenseur et chute de la faceplate.
  • Page 84 9. FONCTIONNEMENT Direction du flux d'air et de l'oscillation de haut en bas (sur certains modèles) SWING SWING Utilisez le bouton pour régler la direction du flux d’air haut-bas. 1. Appuyez sur le bouton à chaque fois, les sautes d'persienne 6 degrés. 2.
  • Page 85: Fonctions De Minuterie

    10. FONCTIONS DE MINUTERIE Minuterie hebdomadaire Utilisez cette fonction de minuterie pour régler les temps de fonctionnement pour chaque jour de la semaine. Allumer la minuterie Utilisez cette fonction de minuterie pour démarrer le fonctionnement du climatiseur.La minuterie fonctionne et le fonctionnement du climatiseur démarre une fois le délai écoulé.
  • Page 86 10. FONCTIONS DE MINUTERIE Pour régler la minuterie On ou Off Appuyez sur le bouton TIMER pour sélectionner TIMER No display Appuyez sur le bouton CONFIRMER et l'affichage de l'horloge clignotera. CONFIRM ex. TIMER OFF 6:00 PM Appuyez sur le bouton « + » ou « - » pour régler l'heure. Une fois l'heure réglée, la minuterie démarrer ou arrêter automatiquement.
  • Page 87 10. FONCTIONS DE MINUTERIE Pour régler la minuterie On ou Off Appuyez sur le bouton TIMER pour sélectionner TIMER Appuyez sur le bouton CONFIRMER et l'affichage de l'horloge clignotera. CONFIRM CONFIRM Appuyez sur le bouton « + » ou « - » pour régler l'heure sur minuterie, puis appuyez sur le bouton CONFIRMER pour confirmer le réglage.
  • Page 88: Minuterie Hebdomadaire

    11. MINUTERIE HEBDOMADAIRE Réglage de la minuterie hebdomadaire TIMER CONFIRM Appuyez sur le bouton Puis appuyez sur le bouton TIMER pour sélectionner pour CONFIRMER Ajustement des jours de la semaine CONFIRM Appuyez sur le bouton « + » ou « - » pour sélectionner le jour de la semaine et puis appuyez sur le bouton CONFIRMER pour confirmer le réglage.
  • Page 89 11. MINUTERIE HEBDOMADAIRE ex. Échelle de temps du mardi 1 Jusqu'à 4 réglages de minuterie peuvent être sauvegardés pour chaque jour de la semaine. Il est pratique que le HEBDOMADAIRE soit réglé en fonction du style de vie de l’utilisateur. Off réglage de la minuterie de réglage de la minuterie CONFIRM Appuyez sur le bouton «...
  • Page 90 11. MINUTERIE HEBDOMADAIRE Fonctionnement de la minuterie hebdomadaire À activer le mode MINUTERIE ● Appuyez sur le bouton minuterie pendant est affiché sur l'écran LCD. TIMER ● À désactiver le fonctionnement MINUTERIE HEBDOMADAIRE TIMER Appuyez sur le bouton minuterie pendant est disparaître de l'écran LCD.
  • Page 91 11. MINUTERIE HEBDOMADAIRE À régler le jour de repos (pour un séjour) Pendant la minuterie hebdomadaire, appuyez sur le bouton CONFIRMER. CONFIRM Appuyez sur le bouton « + » ou « - » pour sélectionner le jour dans la semaine. Appuyez sur le bouton DAY OFF pour régler la journée.
  • Page 92 11. MINUTERIE HEBDOMADAIRE Fonction RETARD Pendant la minuterie hebdomadaire, en appuyant une fois sur le bouton DELAY, afficher Appuyez sur ce bouton deux fois, l'écran affichera et attendez 3 secondes pour confirmer. Cela signifie que l'unité écrasera 1 heure; Appuyez sur cette touche trois fois, affichage et attendez 3 secondes pour DELAY/DAY OFF...
  • Page 93 11. MINUTERIE HEBDOMADAIRE Appuyez sur le bouton Copier, la lettre « CY » sera affiché sur l'écran LCD. COPY Appuyez sur le bouton « + » ou « - » pour sélectionner le jour de la copie. Appuyez sur le bouton COPY pour confirmer. CO PY La marque clignotera...
  • Page 94: Gestion De L'alarme D'erreur

    12. GESTION DE L'ALARME D'ERREUR Si le système ne fonctionne pas correctement, sauf les cas mentionnés ci- dessus ou les dysfonctionnements mentionnés ci-dessus sont évidents, examinez le système en suivant les procédures suivantes. AFFICHAGE D E F A U T D E F O N C T I O N N E M E N T &...
  • Page 95 Visítanos en: www.easelectric.es EAS ELECTRIC SMART TECHNOLOGY, S.L.U. P.I. San Carlos, Camino de la Sierra S/N, Parc. 11 03370 Redován - Alicante (SPAIN)

Table of Contents