Meditech ABPM-05 User Manual

Meditech ABPM-05 User Manual

Ambulatory blood pressure monitors
Hide thumbs Also See for ABPM-05:

Advertisement

User Guide
ABPM-05 & BlueBP-05
Ambulatory Blood Pressure Monitors

Advertisement

Table of Contents
loading

Summary of Contents for Meditech ABPM-05

  • Page 1 User Guide ABPM-05 & BlueBP-05 Ambulatory Blood Pressure Monitors...
  • Page 2: Table Of Contents

    3. Test communication ............................9 4. Program the monitor ............................. 10 6. Retrieve data ................................. 11 7. Customize, review & print data ....................... 12 ABPM-05 manual programming ........................12 Patient information ..............................13 Cuffs .....................................14 Dimensions ................................14 Application ................................. 15 Batteries ...................................
  • Page 3: Product Description

    Product Description Meditech ABPM-05, and its Bluetooth-capable version BlueBP-05, provides accurate information on blood pressure variability, overnight dipping and morning surge for reliable hypertension management and control. Both ambulatory blood pressure monitors incorporate an algorithm validated to BHS (British Hypertension Society) and AAMI (Association for the Advancement of Medical Instrumentation) protocols.
  • Page 4: Lcd Display

    LCD display Information displayed on both ABPM-05 and BlueBP-05. Normal status: time Pulse rate value of is displayed. just completed measurements (beats/minute) Blood pressure Event marker set measurement during a button initiated (mmHg) push Pumping for Error code display measurement,...
  • Page 5: Buttons

    Information displayed on ABPM-05 only Communication Blood pressure with a personal measurement computer initiated (kPa) Pumping for Deflation during measurement, measurement, current pressure is current pressure displayed (kPa) displayed (kPa) Systolic value of a Heart symbol just completed blinking: measurement (19,2...
  • Page 6 Start button functions to start a manual blood pressure measurement (press shortly) Typical causes for this use: dizziness, pain (angina pectoris or headache), palpitation. to switch the device off (press and hold for more than 10 seconds) Press and hold the Start button until 2 horizontal segments appear on the LCD ( - - ).
  • Page 7: How To Use The Monitor

    2.2 Setup communication between the monitor and the PC ABPM-05 ABPM-05 works with a special USB optical cable, which connects the monitor to your PC. Always install the software before connecting the USB optical cable to the PC! (The USB driver is installed together with the software, in the absence of which the PC will not recognize the interface.)
  • Page 8 Connect the interface unit to the port. Connect the recorder to the optical cable. If a Meditech USB optical interface cable has been supplied to your monitor, always install the USB driver before connecting the USB cable to the computer! The USB driver can be installed with CardioVisions software installation! The interface unit converts optical signals to electric ones and vice versa.
  • Page 9: Test Communication

    Help as well. 3. Test communication ABPM-05  CardioVisions: Tools/Options/Communication. Select ABPM-05, select the type of your interface unit, select the required port or simply click on Test.  EasyABPM: Device/Read data. BlueBP-05 If you want to use a BlueBP-05 with Bluetooth under Windows XP SP 2, follow the steps below.
  • Page 10: Program The Monitor

    Make your device Bluetooth-discoverable by pressing the Start and the Event button simultaneously for longer than 3 seconds, and then release them. The LCD displays the PC-- marking, indicating the recorder is discoverable. The recorders remain discoverable for a minute then switches back to standby mode.
  • Page 11: Retrieve Data

    4.4 Send the monitoring plan from the computer to the recorder unit. 5. Fit the patient with the monitor 5.1 Apply a proper-size cuff to the patient’s non- dominant arm and be sure that the artery indicator is over the brachial artery. 5.2 Connect the hose to the monitor.
  • Page 12: Customize, Review & Print Data

    7.3 Create and save or print the report ABPM-05 Manual Programming ABPM-05 if programmed manually can be used by CardioVisions software 1.13 or later versions. Plans are stored in the inbuilt memory of the device and they cannot be changed. The following three measurement plans can be selected during the programming of the device: PLAN A): measurements every 15 minutes at day and every 30 minutes at night.
  • Page 13: Patient Information

    如果是手动编程,则没有时间设置。如果时间设置不精确,则测量时间可能是错误的。如果要使用手动编程功能,请不要让设备长时间没有 电池。如果可能发生这种情况,请将电池重新插入设备,通过PC对设备进行编程来设置内部时钟,并将电池留在设备中(建议的周期为24 小时)。第一次测量具有控制目的,在编程后的第二分钟开始,然后在接下来的五分钟内不能开始其他测量。其余的测量以特定的 15/20/30/40分钟间隔进行,在6:00和22:00小时轮班进行测量。最后一次测量正好是第二次测量后24小时。 imprecise, the time of measurements may be false. If you want to use the manual programming function, do not leave the device without batteries for a longer period. If it could happened so, insert batteries again into the device, set the inner clock by programming the device by a PC and leave the batteries in the device (the suggested period is 24 hours).
  • Page 14: Cuffs

    Press any button to stop a blood pressure measurement. Should the blood pressure measurements cause bloodshots, torpidity or pain in the hand, the cuff should be removed from the arm immediately and disconnected from the recorder. Such occurrence should be reported to the physician latest after the monitoring session.
  • Page 15: Application

    Application Set the cuff size during programming the monitor The monitors recognize three different cuff sizes. The size to be used should be set during programming of the device. Inappropriate setting of the cuff size may lead to device malfunctioning, which is inconvenient for the patient and may lead to an unsuccessful measurement.
  • Page 16: Batteries

    The cuff is the component which, by definition of the relevant standard, is protected against a defibrillator discharge. The substitution of a cuff different from that supplied by Meditech might result in measurement error and/or in certain cases it causes damage to the main recorder unit.
  • Page 17: Safety Concerns

    Many personal computers do not meet shock hazard protection standards or strict safety regulations applicable to medical devices. Therefore, during the computer- based use of Meditech recorders, keep at least a 2 meter distance between the patient and the computer. This is the required minimum safety distance. ABPM-05 communicates via a plastic optical cable, the 3 m standard length of which allows for the required safety distance.
  • Page 18: Cleaning & Protection

    They emit no material hazardous to humans. Risk of incorrect diagnosis The basic intended use of Meditech recorders is to record blood pressure and pulse rate values. Patients should be informed about rules of cooperative behavior;...
  • Page 19: Maintenance

    Verification of the pressure measurement accuracy is recommended biannually. All the devices are covered by a two-year warranty under general warranty conditions of Meditech Ltd, see relevant topic. This warranty does not cover any malfunction or defects arising from improper use, the use of inadequate accessories, accident, theft, or use of the device outside operating environmental specifications or intended measurement range.
  • Page 20: Indications, Contraindications

    Parkinson’s disease or other diseases with tremor. Possible Accessories list USB interface cable (ABPM-05); Bluetooth USB dongle (BlueBP-05) pouch for the recorder with shoulder and waist straps normal size cuff 2 sets of AA long-life battery (recommended capacity: min.
  • Page 21: Technical Specifications

    Technical Specifications Technical Parameters ABPM-05 BlueBP-05 power supply 2 AA rechargeable NiCd or NiMH batteries or 2 AA alkaline batteries display liquid-crystal data storage internal solid state memory data transmission USB optical cable serial Bluetooth transfer operating environment device temperature 10-45 °C...
  • Page 22: Error Codes

    The device does not start automatic measurement until the next programming. Meditech product warranty information RECORDER WARRANTY. The main recorder unit will be free from defects in materials and workmanship under normal use and service for a period of two (2) years from the date of receipt.
  • Page 23: Conventions

    This warranty is valid at the representative address of Meditech Ltd. unless otherwise displayed upon a commercial invoice or any other valid business document duly signed by the supplier and the recipient of the Meditech product. If such business document displaying a certain site for warranty validity cannot be presented, this warranty is valid at Meditech HQ office in Budapest, Hungary.
  • Page 24 Mail: meditech@meditech.eu Web: www.meditech.eu Contact us for further product and service information. Meditech Ltd. maintains a quality assurance system certified according to ISO 9001:2008 and ISO 13485:2003. Notified body: SGS United Kingdom Ltd.; 202B Worle Parkway, Weston-super Mare, BS22 WA, UK; Fax: +44 151 350 6600 Always consult a physician for the interpretation of the blood pressure measurements.
  • Page 25 The device communicates via Bluetooth connection. (Bluetooth V2.0+EDR, class2) Blood pressure measurements determined with the algorithm of an ABPM-05, or a BlueBP-05 recorder on adults are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method Korotkoff phase V, within the limits prescribed by the American National Standard for Electronic or Automated Sphygmomanometers.
  • Page 26: Emc Information

    RF transceivers could adversely affect it. Electromagnetic emission Meditech ambulatory blood pressure monitors are suitable for use in the specified electromagnetic environment. The purchaser or user of the device should assure that they are used in an electromagnetic environment as described below.
  • Page 27 Monitor Immunity test IEC60601 test Compliance Electromagnetic environment level level ABPM-05 & Voltage dips, short <5% UT (>95% dip) Mains power quality is that of BlueBP-05 interruptions and for 0.5 cycle; applicable a typical commercial and/or voltage variations 40% UT (60% dip) hospital environment.
  • Page 28 Recommended separation distance Meditech ambulatory blood pressure monitors are intended to be used in electromagnetic environment with controlled RF disturbances. The purchaser or user of the devices may help to reduce electromagnetic disturbances by defining separation distance between transportable mobile telecommunication equipment (transmitters) and the device, depending on the highest output power of the telecommunication equipment.

This manual is also suitable for:

Bluebp-05

Table of Contents