Pressure transmitter

Advertisement

Accuracy: ≤±0.25%FS
Note: The precision of products is related to the range of measurement,
and the precision of products in different range is different.
Long-term Stability:≤±0.3%FS/year
Zero Temperature Drift: ≤0.05%FS/℃ (≤100kPa), ≤0.03%FS/℃(>
100kPa)
FS Temperature Drift: ≤0.05%FS/℃ (≤100kPa), ≤0.03%FS/℃(>
100kPa)
Power Supply:11V~28V DC(intrinsic safe version supplied through safe
barrier),3.3V/5V DC
Signal Output:4mA~20mA DC (2-wire 11V~28V DC Power Supply)
0/1V~5V/10V DC (3-wire 11V~28V DC Power Supply)
0.5V~2.5/4.5VDC (3-wire 3.3V/5V DC Power Supply)
Compensation Temperature Range: 0℃~50℃
Operation Temperature:
≤±0.5%FS
-30℃~80℃ (4-pin Plug, M12x1 Plug)
-20℃~70℃(Cable type, cable material: PE, PVC)
-20℃~80℃(Cable type, cable material: PUR)
-30℃~60℃(Intrinsic safety , 4-pin Plug)
-20℃~60℃(Intrinsic safety ,cable)
≤±1%FS