Remote Controller; Wireless Remote Controller - Fujitsu AUTG09LVLB Design & Technical Manual

Cassette type
Table of Contents

Advertisement

2. Remote controller

2-1. Wireless remote controller

 Features
 Built-in timers
Selectable from 4 different timer programs (on, off, program, and sleep).
 Program timer
The program timer operates the on and off timer once within a 24-hour period.
 Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to
the time setting to prevent excessive cooling and heatingwhile sleeping.
Cooling operation/Dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
60 min
 Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
• 4 kinds of timer setup (on/off/program/sleep) are possible.
• Can be used jointly with wired remote controllers.
• Easy to change custom code (max. 4 custom codes) by button
operation.
Timer setting
2 °C
1 °C
- 4 -
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The
set temperature can drop to a maximum of 4 °C.
1 °C
2 °C
30 min
60 min
90 min
Timer setting
3 °C
4 °C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Autg12lvlbAotg09lbcbAotg12lbcb

Table of Contents