PC/VIEW & PC/180 TROUBLE SHOOTING GUIDE
Below are outlined the 3 most common conflicts encountered using PC/View and PC/180. Please
read the entire document before attempting any changes to the computer system or PC/View or
PC/180 programs Typically, these conflicts are noted by the message "PC32 sonar not found.
Switch to demo mode?" This indicates some conflict in the computer that prevents it from finding
the equipment via the parallel port. Other messages may appear as noted below.
PC's running Win2K and WinXP will always need setting changes to run the program.
1.
Standard parallel port conflict: The PC/View and PC180 use interrupt IRQ 7 to communicate
with the hardware via standard parallel port. Some computers may have another device
installed that will also try to load on IRQ 7, creating a conflict. We will use Soundblaster as an
example. When the driver is loading "aggressively" on IRQ 7 at boot time, the interrupt will be
taken from the PC/View or PC180, and any other interrupt-driven application.
Note: many parallel port applications, such as printer drivers, are not interrupt-driven and
therefore do not suffer when this conflict exists.
There are two ways of addressing the conflict:
1. Use the port before the Soundblaster can.
2. Switch the Soundblaster to use another IRQ.
There are two ways to to resolve this conflict for Win95 and Win98. In order of preference they
are:
A. Use the Device Manager to switch the Soundblaster's interrupt. There are many ways to get to
the Device Manager. Perhaps the easiest to describe is through 'My Computer'. Here's the
process for Windows 95/98:
1. Right click on the 'My Computer' icon (usually upper left of desktop).
2. Select the 'Properties' option.
3. Select the 'Device Manager' tab.
4. Right click on the 'Computer' icon at the top of the Device Manager box.
5. Select the 'Properties' option.
6. Select the 'Reserve Resources' tab.
7. Click on the 'Add' button.
8. Type "07" in the edit box.
9. You will now see a little "07" in the Reserved Resources box.
10. Reboot.
11. If you watch the boot cycle carefully, you should see the Soundblaster load on IRQ 5.
12. If your system acts funny or gives you new LPT messages/warnings, just revert to the
unreserved IRQ and try our DriverLoadMethod.exe.
________________________________________________________________________
2880 Research Park Drive, Suite 140, Soquel CA 95073 Phone: 831-477-9685 Fax: 831-462-7444
Web Site: www.interphase-tech.com E-mail: comments@interphase-tech.com
Forward Looking Technology
I N C.

Advertisement

loading

Summary of Contents for Interphase PC/180

  • Page 1 Forward Looking Technology PC/VIEW & PC/180 TROUBLE SHOOTING GUIDE Below are outlined the 3 most common conflicts encountered using PC/View and PC/180. Please read the entire document before attempting any changes to the computer system or PC/View or PC/180 programs Typically, these conflicts are noted by the message “PC32 sonar not found.
  • Page 2 I/O range can be changed here. It is possible to change the LPT Port Address within the PC/View and PC/180 to match other I/O settings on the PC. This is not preferred, but can be attempted if the preferred settings are not operating.
  • Page 3 12. The message “ You adjusted one or more settings manuall. If you continue, these settings will be assigned to the device. Do you want to continue?” will appear. Click on ‘Yes’. In addition, it is ESSENTIAL that the Port Settings allow PC/View or PC/180 to to use the port. 1. Follow steps 1-6 above.
  • Page 4 4. Select ‘Bi-Directional’. Note: Output Only, ECP and EPP are also available. In our tests using a Dell Dimension 4400 running WinXP(HE) the ‘Bi-Directional‘ setting allowed PC/View and PC/180 to run. No other bios setting worked. This has also been confirmed to work on XP Pro.
  • Page 5 Forward Looking Technology Also under this selection there are the following options: “Run in 256 Colors”, “Run in 640x480 screen resolution”, “Disable Visual Themes”. ALL of the options should be unselected for best visual performance of PC/View and PC/180. October 2002 ________________________________________________________________________ 2880 Research Park Drive, Suite 140, Soquel CA 95073 Phone: 831-477-9685 Fax: 831-462-7444 Web Site: www.interphase-tech.com E-mail: comments@interphase-tech.com...