Both Interfaces In Rs232 Mode; Connection Of The First Serial Interface Switched To Rs232 Mode; Connection Of The Second Serial Interface Switched To R232 Mode - Advantech ICR-2834 User Manual

Lte industrial router
Hide thumbs Also See for ICR-2834:
Table of Contents

Advertisement

If switches are switched on, serial interfaces are switched to operate as RS232, see Fig-
ure 12, Table
8
and Table 9.
Pin
Signal mark
1
RXD
TXD
2
3
RTS
4
CTS
GND
5
Table 8: Connection of the first serial interface switched to RS232 mode
Pin
Signal mark
9
RXD
TXD
10
11
RTS
12
CTS
GND
13
Table 9: Connection of the second serial interface switched to R232 mode
The serial interfaces are not eletrically isolated from the router.
Figure 12: Both interfaces in RS232 mode
Description
Received Data
Transmit Data
Request to Send
Clear to Send
Ground
Description
Received Data
Transmit Data
Request to Send
Clear to Send
Ground