AirKing MQFAM Important Instructions & Operating Manual

AirKing MQFAM Important Instructions & Operating Manual

Inline fan
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT INSTRUCTIONS - OPERATING MANUAL
MQFAM, MFAS
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel
and lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-
related construction.
b) Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA) and the American Society for Heating, Refrigeration,
and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6728092 Rev. E 4/22
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) This unit must be grounded.
e) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
f) Read all instructions before installing or using exhaust fan.
g) For residential installations only.
h) Must use suitable weather hood with insect screen to protect air intake.
WARNING:
REMOVE ANY SHIPPING MATERIAL THAT MAY BE
PRESENT INSIDE THE UNIT.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE
AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST,
STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE,
AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE
ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH
EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Inline Fan
FOR GENERAL VENTILATING USE ONLY.
TO REDUCE THE RISK OF FIRE,
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY
SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MQFAM and is the answer not in the manual?

Questions and answers

Summary of Contents for AirKing MQFAM

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL MQFAM, MFAS Inline Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    WARNING: MAKE SURE THE FRESH AIR INTAKE PORT COMPLIES WITH 2 - Collar Assembly (attached) 1 - Controller (attached) (MQFAM only) ALL LOCAL AND NATIONAL CODES AND IS LOCATED AT LEAST 6 FEET AWAY 2 - Mounting Brackets (attached) 1 - Instruction/Safety Sheet FROM SOURCES OF CONTAMINATION SUCH AS BUT NOT LIMITED TO: DRYER, Choose the location for your fan.
  • Page 3 Filters must be changed Restore power and test your installation. regularly. Refer to the filter manufacturer’s Figure 8 SECTION 8 (MQFAM Only) recommendations to determine how often the filter should be changed. Using the Controller Remove the screw securing the access panel cover in place and open the cover to gain On Mode: Fan will run continuously when the ON button ( ) is pressed.
  • Page 4: Troubleshooting Guide

    When connected to the MQFAM, the motorized damper will open when the MQFAM is energized and will close when the MQFAM turns off. The MD624 also requires a MQMDB In the normal operation display, press and hold the “SetT” button for 5 seconds to switch the receptacle box (sold separately).
  • Page 5: Limited Warranty

    LIMITED WARRANTY WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials. HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for three (3) years from the date of original purchase or until the original purchaser of the product sells or transfers the product, whichever first occurs.
  • Page 6: Replacement Parts Diagram

    Mounting Brackets 5S1650001 6" Metal Collar (Intake) 5S1650030 6" Metal Collar (Outlet) 5S1650029 Blower Assembly 5S1650031 Wire Compartment Assembly 5S1650032 LCD Controller (MQFAM) 5S1650043 Insect Screen 5S1650028 Harness 5S1650033 Access Panel 5S1650042 www.airkinglimited.com 6728092 Rev. E 4/22 6 of 12...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION MQFAM, MFAS Ventilateur en série LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 : les ventilateurs installés avec des conduits existants n’atteignent pas leur débit d’air nominal. 2 - Assemblage de collier (attaché) 1 - Contrôleur (attaché) (MQFAM Seulement) AVERTISSEMENT: ASSUREZ-VOUS QUE LE PORT D’ADMISSION 2 - Traverses de Montage (attaché) 1 - Feuillet d’instructions / sécurité...
  • Page 9 6. Restaurer l’alimentation et tester votre installation. boîtier. Assurez-vous que le filtre est bien en place jusqu’au fond du boîtier (Figure 9). SECTION 8 (MQFAM Seulement) Utiliser le contrôleur Mode allumé : Le ventilateur fonctionnera en continu lorsque le bouton ON ( ) est enfoncé.
  • Page 10: Guide De Dépannage

    Lorsqu’il est connecté au MQFAM, l’amortisseur motorisé s’ouvre lorsque le MQFAM est activé et le couvercle de contrôle à Figure 12 se ferme lorsque le MQFAM s’éteint. Le MD624 requiert également une boîte de prise MQMDB partir du dessus (Figure 12). (vendue séparément).
  • Page 11: Garantie Limitée

    GARANTIE LIMITÉE QUE COUVRE CETTE GARANTIE : Ce produit est garanti contre tout vice de fabrication ou de matière. COMBIEN DE TEMPS CETTE GARANTIE DURE : Cette garantie se rapporte seulement à l’acheteur original du produit et dure pendant trois (3) années de la date de l’achat original ou jusqu’à...
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT Qte. Description # de pièce remplacement Support de montage 5S1650001 Assemblée de collier en métal de 6 po (d’admission) 5S1650030 Assemblée de collier en métal de 6 po (sortie) 5S1650029 Assemblée de la Soufflante 5S1650031 Assemblée du compartiment du fil 5S1650032 Contrôleur LCD (MQAMF)

This manual is also suitable for:

Mfas

Table of Contents