Troubleshooting - NORPOLE NP1R User Manual

Commercial refrigerator and freezer
Hide thumbs Also See for NP1R:

Advertisement

TROUBLE SHOOTING
Before requesting any service on your unit, please check the following points.
Please note that this guide serves only as a reference for solutions to common
problems.
SYMPTOM
POSSIBLE CAUSE
Compressor
Fuse blown or circuit breaker tripped.
not running.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Condensing
Excessive amount of warn product
unit runs for
placed in cabinet.
long
periods
Prolonged door opening or door ajar.
of time.
Door gasket(s) not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
Cabinet
Thermostat set too warm.
temperature
is too warm.
Blocking air flow.
Excessive amount of warm product
placed in cabinet.
Fuse blown or circuit breaker tripped.
Dirty condenser coil.
Prolonged door opening or door ajar.
CORRECTIVE ACTION
Replace fuse or reset circuit
breaker.
Plug in power cord.
Set thermostat to lower
temperature.
Wait for defrost cycle to finish.
Allow adequate time for
product to cool down.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
Ensure gaskets are snapped in
completely. Remove gasket and
wash with soap and water.
Check condition of gasket and
replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure thermostat is
not set too cold. Ensure that
door gasket(s) are sealing
properly.
Set thermostat to lower
temperature.
Re-arrange product to allow for
proper air flow. Make sure there
is at least four inches of
clearance from evaporator.
Allow adequate time for
product to cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when
not in use. Avoid opening doors
- 5 -