Installation Information
Installation Specifications (Integrated) - Starting with Serial #13005870
The illustration below shows the rough-in dimensions for an "Integrated" warming drawer installation below a wall
oven
(See Figure 2-3).
NOTE:
Prior to serial #13005870, the warming drawer could not be installed in an Integrated application.
For complete installation instructions, refer to the installation guide.
NOTE:
1.5" X 1.5"
(3.8 mm X 3.8 mm)
Anti-Tip Block
must be installed.
* Dimension may vary by ± 1/8" ( ± 3 mm)
E = Electrical outlet location
NOTE:
Figure 2-3. Integrated Warming Drawer Installation below a Wall Oven
#802981 Rev. A Jan. 2005
NOTE:
Minimum required cabinet width = 33" (838 mm)
Minimum required cabinet depth = 26" (660 mm)
5"
(127)
E
*29-15/16"
(760)
(264)
Dimensions in parentheses are in millimeters.
WARMING DRAWER
4"
(102)
NOTE:
If installed below Wolf
25-1/2" min
wall oven, rail between
(648)
appliances must be
minimum 2-3/8" (60 mm) thick.
23"
(584)
BACK OF
UNIT TO
BACK OF
FRAME
2-4
FRAME
10-1/4"
(260)
FRAME
29-7/8"
(759)