BLACKMER AX65 Installation Operation & Maintenance

BLACKMER AX65 Installation Operation & Maintenance

Peristaltic hose pump

Advertisement

Quick Links

BLACKMER PERISTALTIC
HOSE PUMP AX65
BLACKMER
ZI PLAINE DES ISLES
F- 89000 AUXERRE
Technical Assistance / Repair . . . . .Tél. : 03.86.49.86.03
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fax : 03.86.49.86.48
Spare parts / Advice . . . . . . . . . . . .Tél. : 03 86.49.86.02
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fax : 03.86.49.86.28
e-mail : contact@blackmer-mouvex.com
Votre distributeur / Your distributor / Ihr händler
TECHNICAL
INSTRUCTIONS
INSTALLATION
MAINTENANCE
BLACKMER GmbH
Auf dem Zehnthöbel 22
D-64572 BUTTELBORN - WORFELDEN
Tel : .......................................+49/6152/9869-0
Fax :
e-mail : willkommen@blackmer-mouvex.com
1101-
K01(e)
Revision
B
OPERATION
+49/6152/9869-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AX65 and is the answer not in the manual?

Questions and answers

Summary of Contents for BLACKMER AX65

  • Page 1 TECHNICAL 1101- INSTRUCTIONS K01(e) Revision BLACKMER PERISTALTIC HOSE PUMP AX65 INSTALLATION OPERATION MAINTENANCE BLACKMER BLACKMER GmbH ZI PLAINE DES ISLES Auf dem Zehnthöbel 22 F- 89000 AUXERRE D-64572 BUTTELBORN - WORFELDEN Technical Assistance / Repair ..Tél. : 03.86.49.86.03 Tel : …………………………………+49/6152/9869-0...
  • Page 2: Table Of Contents

    SLIPPERY AND MAY CAUSE Warning of a danger that MAY CAUSE serious injury SERIOUS INJURY. ANY SPILLS NOTE: MUST BE CLEANED UP. Indicates very important special instructions that must be observed. IOM - Abaques series - Model AX65 - Blackmer 1/16...
  • Page 3: Operating Principle

    CAPABLE OF LIFTING switch against overloads. THIS SWITCH MUST THE WEIGHT OF THE NOT HAVE AUTOMATIC REACTIVATION. If such PUMP. protection is not provided, the motor may start running unexpectedly. IOM - Abaques series - Model AX65 - Blackmer 2/16...
  • Page 4: Mechanical Risks

    ING. VALVE CLOSED MAY CAUSE SYSTEM BREAKDOWN, PER- SONAL INJURY AND PROPERTY DAMAGE. Wear safety gloves when replacing the hose. Keep your hands away from the inlet and discharge flanges. 3/16 IOM - Abaques series - Model AX65 - Blackmer...
  • Page 5: Extended Storage

    (bends, Therefore, the pump may be re-started more easily. T-joints, etc.) and valves possible, l have the largest bending radius possible in order to reduce pressure drops. IOM - Abaques series - Model AX65 - Blackmer 4/16...
  • Page 6: Maintenance Operations

    Evacuation of this fluid may also be carried out by running the pump after having taken all the safety measures required for personal and property protection. Operate the pump intermittently until the hose is com- pletely out. IOM - Abaques series - Model AX65 - Blackmer 5/16...
  • Page 7 DO NOT STAND IN FRONT OF THE OUTLET AXIS OF THE BE CAREFUL WITH THE HOSE TO PREVENT BEING WEIGHT OF THE COVER WHEN THROWN OR HIT BY THE HOSE REMOVING IT. IOM - Abaques series - Model AX65 - Blackmer 6/16...
  • Page 8 Firmly tighten clamp (9) onto hose (16). Put the leak detection kit back in place, if the pump is DISCHARGE FLANGE: equipped with one. Repeat the operations described above for the dis- charge side. IOM - Abaques series - Model AX65 - Blackmer 7/16...
  • Page 9: Re-Assembling And Disassembling The Wheel

    See the technical instruc- Screws (20a) must not be tightened so the tions in paragraph 6.2 “SHIMMING THE SHOES”. wheel assembly can freely slide along the axis. 8/16 IOM - Abaques series - Model AX65 - Blackmer...
  • Page 10: Installing The Shims

    Untighten the screw (37) and remove the washers (38), the window (15) and its seal (46). Partially untighten the shoe screws (28). NOTE: Do not loosen the shoe screws completely. IOM - Abaques series - Model AX65 - Blackmer 9/16...
  • Page 11: Technical Specifications

    6.3. HOSE No additional shimming is needed. There are three different types of hose materials: NR, NBR, EPDM The maximum operating pressure permitted is 15 bars (217.5 PSI). IOM - Abaques series - Model AX65 - Blackmer...
  • Page 12: Dimensions

    6.4. DIMENSIONS 6.4.1. Model AX65 11/16 IOM - Abaques series - Model AX65 - Blackmer...
  • Page 13 6.4.2. Model ASX65 12/16 IOM - Abaques series - Model AX65 - Blackmer...
  • Page 14 Drawn by : PR Checked by : SP blackmer Gross Machined Weight : weight : 2, rue des caillotes, 89 000 Auxerre EXPLODED VIEW AX65 / AX80 A2 N° 61281 IOM - Abaques series - Model AX65 - Blackmer 13/16...
  • Page 15: Maintenance

    Please note that operation of the pump with fluid at a temperature above 60°C (140°F) requires a mandatory reduction in pump rotation speed. When required, con- tact your local dealer for advice. 14/16 IOM - Abaques series - Model AX65 - Blackmer...
  • Page 16: Troubleshooting

    Add lubricant (See paragraph 7.1 “LUBRICATION”) Temperature of the pumped fluid Check the maximum fluid temperature is too high. allowed for the hose material. Pump speed too high. Reduce speed. 15/16 IOM - Abaques series - Model AX65 - Blackmer...