Woodbridge DV32CV Installation And Operating Instructions Manual

Woodbridge DV32CV Installation And Operating Instructions Manual

Direct vent gas fireplace with standing pilot system

Advertisement

Quick Links

WARNING: This
fireplace requires
18 inches of vertical
venting before
any horizontal runs
WARNING: FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in
serious injury, death, or property damage.
– Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
– Installation and service must be per formed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. Refer to this manual. For assistance or
additional information consult a qualified installer,
service agency or the gas supplier.
This appliance may be installed in an aftermarket,
permanently
located,
only) or mobile home where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
conver tible for use with other gases, unless a certified
kit is used.
Version française de ce manuel est disponible à partir du site WEB : www.woodbridgedealer.com
French version of this Owners Manual is available at www.woodbridge dealer .com
W oodbridge F ireplace I nc .
DIRECT VENT GAS FIREPLACE WITH
STANDING PILOT SYSTEM
MODELS: DV32CV(N,P)
INSTALLATION AND OPERATING INSTRUCTIONS
manufactured
home (USA
Report # 0401GF024S
DUE
TO
HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT
OF TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
CHILDREN AND ADULTS
ALERTED TO THE HAZARDS
SURFACE TEMPERATURE AND SHOULD
STAY
AWAY
TO
CLOTHING IGNITION.
Y OUNG
CHILDREN
S UPERVISED WHEN THEY ARE IN THE
S AME ROOM AS THE APPLIANCE.
C LOTHING OR
M ATERIAL SHOULD NOT BE PLACED ON
O R NEAR THE APPLIANCE.
K EEP THE ROOM AREA
F REE FROM COMBUSTIBLE MATERIALS,
GASO- LINE, AND OTHER FLAMMABLE
V APORS AND LIQUIDS
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
SHOULD BE
OF HIGH
AVOID
BURNS
OR
SHOULD
BE
OTHER FLAMMABLE
CLEAR AND
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV32CV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Woodbridge DV32CV

  • Page 1 INSTALLER: Leave this manual with the appliance. kit is used. CONSUMER: Retain this manual for future reference. Version française de ce manuel est disponible à partir du site WEB : www.woodbridgedealer.com French version of this Owners Manual is available at www.woodbridge dealer .com...
  • Page 2: Table Of Contents

    CONTENTS Important Safety Information ......3 Electrical Installation........28 Electrical Wiring ........28 Product Features..........5 Code Approval ..........5 Glass Removal ..........29 Pre-Installation Information......6 Final Installation........... 30 Installing Above 2000 Feet ......6 Ember Material Placement ......30 Orifice Sizes, Pressures and BTUs ....
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the owner. Please retain these instructions for future reference. WARNING • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • Any change to this fireplace or its controls can be dangerous. •...
  • Page 4 IMPORTANT SAFETY INFORMATION Continued from page 3 IMPORTANT: 12. Do not use this fireplace to cook food or burn paper or PLEASE READ THE FOLLOWING CAREFULLY other objects. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or 13.
  • Page 5: Product Features

    PRODUCT FEATURES CODE APPROVAL PRODUCT SPECIFICATIONS • The appliance is approved for bed- room or bedsitting room installa- • This appliance has been certified tions. for use with either natural gas or propane gas. See appropriate data • The appliance must be properly plates.
  • Page 6: Pre-Installation Information

    PRE-INSTALLATION INFORMATION INSTALLING ABOVE 2000 FEET • In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations. • In Canada, these appliances are certified for altitudes of 0 – 4,500 ft. ORIFICE SIZES, PRESSURES AND BTUs NATURAL GAS PROPANE GAS Manifold Press: (W.C.)
  • Page 7: Fireplace Framing

    FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 2 and the chart below for your specific installation requirements. See Figure 3 on Page 8 for firebox dimensions. The framing headers may rest on the top of the firebox standoffs.
  • Page 8: Fireplace Dimensions

    PRE-INSTALLATION INFORMATION Top view 26” 2" 25.25" 23.25" 7.5” 10.5" Front view Right side view 33” 32” 44.25" 36.25” 43” 23.25" 25.25" Figure 3 - Fireplace Dimensions...
  • Page 9: Fireplace Location

    PRE-INSTALLATION INFORMATION FIREPLACE LOCATION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
  • Page 10: Securing Fireplace To Floor Or Framing

    4. The cover should maintain an air gap of at least 1/8" between covering material and fireplace to allow for metal fireplace front to expand and contract during operation. 5. PLEASE NOTE: Natural stone products may react to heat by discoloring or cracking. Woodbridge Foreplace is not respon- "...
  • Page 11: Clearances

    CLEARANCES CLEARANCES TO COMBUSTIBLES WARNING Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
  • Page 12: Installation Information

    The following actions will void the warranty on your venting system: • Installation of any damaged venting component. • Unauthorized modification of the venting system. • Installation of any component part not manufactured or approved by Woodbridge Fireplace, Inc. • Installation other than permitted by these instructions.
  • Page 13: Vent Installation

    VENT INSTALLATION WARNING This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems. WARNING A Minimum of 4"...
  • Page 14: Installation Planning

    VENT INSTALLATION INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.
  • Page 15 VENT INSTALLATION FOR HORIZONTAL TERMINATION Inside Corner Detail � � � � � � � � � � � � � ����� � � ������ ������ ����� � ��� ������ � � �������� � � � � � � � �...
  • Page 16 VENT INSTALLATION TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE AND NONCOMBUSTIBLE EXTERIORS � � � ���� ������� � � � � � ���� ������� ������ ������ ������� ������ � � ������� ����� �� ��� �������� � ��� ������ �������� � � ������� ����� ��� ���� ���� �� �...
  • Page 17: Rear Wall Vent Installation

    VENTING INSTALLATION REAR WALL VENT INSTALLATION When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance with 18" of vertical rise minimum. The maximum horizontal distance between the rear of the appliance and the outside of termination with 18" minimum rise is 20"...
  • Page 18 VENT INSTALLATION REAR WALL VENT INSTALLATION (continued) 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “UP” on the vent cap facing up.
  • Page 19: Horizontal Termination Configuration

    VENT INSTALLATION HORIZONTAL TERMINATION CONFIGURATIONS — RIGID VENTING Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The Vent Graph, showing the relationship between vertical and horizontal side wall venting, will help to determine the various dimensions allowable.
  • Page 20 VENT INSTALLATION 90° HORIZONTAL TERMINATION CONFIGURATION — RIGID VENTING (Continued) • If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36" (914 mm) (Fig. 21 A and B) This does not apply if the 90° elbows are used to increase or redirect a vertical rise.
  • Page 21: Below Grade Installation

    VENT INSTALLATION BELOW GRADE INSTALLATIONS — RIGID VENTING When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178mm) below grade level. The 7" (178mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.
  • Page 22: Vertical Through-The-Roof Installation

    (2.5 m) of vent pipe can be used between elbows. See Figure 26. Example: Elbow 1 90° • DV32CV Series fireplaces allow for offsets. This Elbow 2 45° application will require that you first determine the Elbow 3 45° roof pitch and use the appropriate starter kit.
  • Page 23: Installation For Vertical Termination

    VENT INSTALLATION INSTALLATION FOR VERTICAL TERMINATION 1. Determine the route your vertical venting will take. If ceiling joist, Roof roof rafters or other framing will obstruct the venting system, consider Flashing an offset. See Figure 27 to avoid cutting load bearing members. NOTE: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing Wall Strap...
  • Page 24: Cathedral Ceiling Installation

    VENT INSTALLATION 4. Connect a section of pipe and extend up through the hole. NOTE: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose. See Figure 25, page 22. Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air.
  • Page 25: Fireplace Installation

    FIREPLACE INSTALLATION CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. INSTALLING GAS PIPING TO FIREPLACE / BURNER SYSTEM LOCATION WARNING A qualified installer or service person must...
  • Page 26 FIREPLACE INSTALLATION CAUTION WARNING Only persons licensed to work with gas piping A manual shutoff valve must be installed upstream may make the necessary gas connections to of the appliance. Union tee and plugged " this appliance. NPT pressure tapping point should be installed upstream of the appliance.
  • Page 27: Checking Gas Pressure

    CHECKING GAS PRESSURE Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install theappliance. Contact your dealer immediately. To ease installation, a 48"x1/2" flex line with manual shut-off Control knob Ignitor valve has been provided with this appliance.
  • Page 28: Electrical Installation

    ELECTRICAL INSTALLATION REMOTE WALL MOUNTED SWITCH A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junc- tion box at the desired location on the wall. See Figure 35. Do not extend beyond the wall switch wire length provided. NOTE: Extended lengths of wire may cause the fireplace not to function properly.
  • Page 29: Glass Removal

    GLASS REMOVAL 2. Lean the top of the glass frame forward GLASS REMOVAL until it clears u pper 1. Locate 8 (eight) 1/4" nuts holding springs on 4 studs , hold the glass frame inside the fireplace as shown . top and bottom of the glass frame.
  • Page 30: Final Installation

    FINAL INSTALLATION EMBER MATERIAL PLACEMENT 1. Place ember material on burner to provide glowing embers. For best results, pull the material apart into pieces the size of a nickel or smaller. Burner 2. Distribute one layer of material to cover the entire burner.
  • Page 31 FINAL INSTALLATION (continued) 4 . Place the left cross log (# 6 ) as shown. Figure 41 - Placing Left Cross Log 5 . Place the right cross log (# 7 ) as shown. Figure 4 2 - Placing Right Cross Log 6 .
  • Page 32: Safety Screen Installation

    SAFETY SCREEN INSTALLATION WARNING: A barrier (safety screen) designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. IMPORTANT: Safety Screen must be in place when the fireplace is in operation. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's barrier for this appliance.
  • Page 33: Front Trim Installation

    FRONT TRIM INSTALLATION STEP 2: Match up the tabs in the STEP 1: Insert the Right Side Panel panel with the slots in the face and into the opening angling in at the top. slide downward. Make sure the Side Panel is secured properly. Repeat with opposite side panel.
  • Page 34: Operating Instructions

    OPERA TING INSTRUCTIONS LIGHTING your Turn off wall switch or thermostat. Turn off all electric power to the appliance if service to be performed. Open access panel.
  • Page 35: Manually Turning On/Off

    OPERA TING INSTRUCTIONS (continued) Turn manual shutoff valve counterclockwise to OPEN position Open clockwise clockwise C lose access panel.
  • Page 36: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND CONTROL COMPARTMENT Keep the control compartment and burner areas clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
  • Page 37: Vent System

    CLEANING AND MAINTENANCE (continued) WARNING Electrical Grounding Instructions The appliance is equipped with a three-prong (grounding) plug for your protection against shock hazzard and should be plugged into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person.
  • Page 38: Troubleshooting

    TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will not A. Wire disconnected. A. Open door and check to make sure wire is connected to ignitor. light pilot after repeated B. Check for spark at electrode and pilot. If no spark and electrode triggering of piezo.
  • Page 39: Illustrated Parts List

    ILLUSTRATED PARTS LIST L OG SET (P/N M100514)
  • Page 40: Vent Components

    ILLUSTRATED PARTS LIST RIGID VENT COMPONENTS � � � Simpson Duravent Direct Vent Pro Item Qty/Box Description or Woodbridge Part # 58DVA-HC Simpson Horizontal High Wind Horizontal Termination Cap 58DVA-VCH High Wind Vertical Termination 58DVA-06 6” Pipe Length 58DVA-09 9” Pipe Length 58DVA-12 12”...
  • Page 41: Firebox Components

    ILLUSTRATED PARTS LISTS (continued) This list contains replaceable parts used in your fireplace. All replacement parts should be ordered from your installer or from Woodbridge Fireplace Inc.at 1-905- 564 -3 001 or on-line at www.woodbridge dealer .come. PART NUMBER DESCRIPTION...
  • Page 43 The installer should keep a duplicate of this form for their records. Accurate completion of this form is required for warranty coverage and for any technical support by Woodbridge Fireplace Inc. Date Purchased: Purchaser/Dealer:...
  • Page 44: Warranty

    Woodbridge Fireplace Inc. in the appliance are found to be defective in materials or workmanship, Woodbridge Fireplace Inc. will, at its option, replace or repair the defective components at no charge to the original owner. Woodbridge Fireplace Inc. will also pay for reasonable labor costs incurred in replacing or repairing such components for a period of two years from date of installation.

This manual is also suitable for:

Dv32cvnDv32cvp

Table of Contents