Page 2
All rights reserved. This manual may not be reproduced or disseminated in any manner without the prior consent of Butzbach GmbH Industrietore. Butzbach GmbH Industrietore reserves the right to make changes to illustrations and information in this operating manual in order to incorporate technical advances. This operating manual was created with great care and is revised regularly.
Mechanical design ..........................14 ® 5.3.1 NOVOSPRINT Duo ........................14 ® 5.3.2 NOVOSPRINT Mono ........................15 ® 5.3.3 NOVOSPRINT Syncro ........................ 16 ® 5.3.4 NOVOSPRINT SyncroXL......................18 Door leaf construction ........................19 5.4.1 Door skin ............................19 Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Page 4
Operation ..............................27 Electrical connection ......................... 27 7.1.1 Requirement ..........................27 7.1.2 Connection ............................ 27 7.1.3 Commissioning ..........................27 7.1.4 Inspection of safety devices ......................28 System operation ..........................28 Switching the system off ........................29 Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Page 5
Malfunctions and remedies ....................... 38 Dismantling and Disposal ........................39 11.1 Dismantling the system ........................39 11.2 Disposal of the system ........................39 11.3 Customer service address ........................ 39 11.4 Door details............................39 Index ................................. 40 Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
This is a separate document, specific to the door! 1.1.4 Save the manual Save the manual in a safe place in the immediate vicinity of the door system that is accessible at all times. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
/ situations. providing information about explanatory documents, e.g. guidelines, standards, etc. The following presentation is used for labelling instructions: ✔ Requirement for the next described instruction First instruction step Second instruction step etc. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Use in areas where children or unauthorised parties have access to operation of the system Use with accessories and replacement parts, which are not controlled and approved by Butzbach GmbH Industrietore Use without or with non-functioning safety devices ...
Connections that are not made correctly or not professionally may lead to death and extremely severe injuries! In addition, they may lead to the system no longer being able to be operated safely. Work on the electrical system should only be carried out by a qualified electrician. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Page 10
CEE plug is guarded against being plugged in. If multiple people are working on the system, each one must ensure that the main power switch is secured against being turned on without authorisation. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
The system may only be operated by authorised personnel who are familiar with its operation. The operator must ensure that people entrusted with operation of the system have read and understood the operating manual. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
The system operator must ensure that the system is only operated in a technically flawless condition. If there is possible damage, he must immediately have it inspected and repaired by Butzbach GmbH Industrietore. ...
Warning! Risk of injury from non-functioning safety devices! Non-functioning safety devices may lead to death or extremely severe injuries. Regularly check the safety components in accordance with the information in 9.2.1 Inspection of safety components. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Important! This especially applies during door operation and for doors with a low building design. Always stay a sufficient distance back from the door! Never reach into gaps and openings, e.g. at the cross beams! Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
In principal, avoid stopping in the door area. Before operating the door system, ensure that no people or objects are located in the door area. Hanging on and going for a ride during door movement is strictly forbidden! Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Ensure that no people or objects are in the vicinity of the door. Monitor the non-visible areas with additional personnel. Move the emergency operation lever slowly in a controlled manner. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Protection from direct sunlight! Protection from moisture and dampness! Packages may not be stacked! The notices attached to the packaging regarding storage must be followed. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
The door can be opened with control buttons and, as the standard option, closes again after the closing delay time has passed. As an option, the signal to open can also be sent from a detector. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1...
07 Lower mounting bracket 16 Door skin with vision element 08 Functional gap 17 Wire channel (Duo) 09 Upper covering 18 Emergency operation (Duo) * Only for doors in exit paths and escape routes Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
06 Rigid stay bar 14 EMERGENCY OPEN button* 07 Lower mounting bracket 15 Spring breakage monitoring* 08 Functional gap 16 Skin with vision element * Only for doors in exit paths and escape routes Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
06 Stay bar 14 EMERGENCY OPEN button* 07 Lower mounting bracket 15 Spring breakage monitoring* 08 Functional gap 16 Door skin with vision element * Only for doors in exit paths and escape routes Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Page 22
04 Emergency operation 10 Jamb covering 05 Control cabinet; control button; main switch 11 Upper covering 06 Stay bar 12 Door skin with vision element * Only for doors in exit paths and escape routes Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
06 Stay bar 14 EMERGENCY OPEN button* 07 Lower mounting bracket 15 Spring breakage monitoring* 08 Functional gap 16 Door skin with vision element * Only for doors in exit paths and escape routes Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
The self-supporting frame construction is attached to the finished floor with brackets in the side jambs and to ® the lintel with brackets in the cross beams. In the case of the NOVOSPRINT SyncroXL, it is additionally attached with a console for support in the centre. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Note! The components of the drive mechanism (electric motor, drive unit) are shown in the replacement parts list. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
The torsion springs in the spring tubes are monitored for breakage of springs and jamming: if the spring force during the door opening operation is not sufficient to cleanly roll up the skin with sufficient tension, then the Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1...
Page 27
If the control unit is turned on, the door performs a test independently after 24 hours from the last door movement, at the latest: the door is opened once and closed again to check the systems. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1...
BDC E800 control unit). Main switch To disconnect the system from the mains. It can be secured against being turned on again with a hanging lock. Placement On the control cabinet Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Page 29
To disconnect the system from the mains. It can be secured against being turned on again with a hanging lock. 6.1.3.3 TST FU3F Control unit (frequency converter control 4kW) Diagram 8 Front side of control unit TST FU3F (frequency converter control 4kW) Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Operation Press the button Function Command to open the door system Result Door opens Note! Stop the opening command: Press the button again. (The button clicks back out again when it is pressed twice). Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Display elements make the user aware of certain settings and situations regarding elements or the entire door system. The control elements are located, for example, on the control cabinet and are described in the control unit function description. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Other types of operation and the length of the closing delay time can be selected as parameters. Turn on the main switch. The display lights for approx. 5 seconds after operating the main switch. The door is ready for operation. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
✔ If the operator of the door system does not have full visibility during operation, the operator must take appropriate measures to ensure operational safety! ✔ In the standard setting of automatic operation: Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
2 Safety and 3 Other dangers must absolutely be followed. Important! This device is only provided for doors that do not automatically open in the event of a power outage. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
After it reaches its end position, let the lever go. Note! At the same time that the lever is operated and with the emergency operation, the door control unit function is placed out of service. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
In order to fully open the door by hand, the lever for emergency operation can be locked into place. Note! This lock is particularly helpful if there is only one person at the door. This lock is attached to the side of the lever. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Remove the lock from the guide. Normal operation is possible again. Return the lever to its starting position and activate the signal device. The control unit is active again and the door is ready for operation. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Wash the painted surface with water and customarily available mild paint cleaners. Note! For doors that are installed in exit and escape routes, the door skins are only partially accessible for cleaning. In these cases, contact our customer service address. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
3 Other dangers must absolutely be followed! Note! Maintenance work! The maintenance work on the system should fundamentally only be performed by authorised service personnel of Butzbach GmbH Industrietore. The authorised service personnel have a service and maintenance manual.
Note! Function ability of the safety edge! If the safety edge is not functioning properly, first check the batteries in the radio device on the door leaves for versions with radio transmitter. Otherwise, immediately contact our customer service. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Checking connections to the building in accordance with DGUV 208-022 appendix 3 Check whether the required warning signs are attached to the door system. Keep evidence of these tests in the form of a test book. Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
H = Check the skin tension (forming of folds) 8 = Regular cleaning I = Check the switch play (air gap between the brake pad & anchor plate) J = Check for deformation K = Check the shape, correct position Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
In these cases, contact the manufacturer, see the customer service address. Have the commissioning performed by authorised qualified personnel Note! If an owner attempts their own repairs without professional knowledge, this can increase damage and void warranties! Butzbach GmbH Industrietore Originalbedienungsanleitung NOVOSPRINT_V1 24/02/2021...
Service Address. 11.2 Disposal of the system For information regarding disposal of the system, please contact the manufacturer, see Manufacturer's Customer Service Address. 11.3 Customer service address Butzbach GmbH Industrietore Weiherstraße 16 D-89293 Kellmünz Service Centre (domestic): Tel.: 08337 / 901 111...
Need help?
Do you have a question about the NOVOSPRINT Duo and is the answer not in the manual?
Questions and answers