Document N° YA121-07I20.EN
EC
EC
rZ cPIA
6 and cPIA
8
2 pipes heat exchanger
Installation manual
Ceiling version
EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat -
FRANCE Phone : +33 (0)4 42 70 70 30
1
www.eurevia.com
info@eurevia.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the rZ cPIAEC 6 and is the answer not in the manual?

Questions and answers

Summary of Contents for EUREVIA rZ cPIAEC 6

  • Page 1 6 and cPIA 2 pipes heat exchanger Installation manual Ceiling version EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 – www.eurevia.com info@eurevia.com...
  • Page 2 EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...
  • Page 3: Table Of Contents

    Size and maintenance ........................... 14 ACCES MAINTENANCE ........................... 15 FIXATIONS ............................. 15 Notes ................................16 EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 – www.eurevia.com...
  • Page 4: General Precautions

    Make sure that the power supply corresponds to the nominal power supply of the control panel. If necessary, refer to the identification plate on the side of the device or contact EUREVIA Technical Service. The cPIA plant requires systematically a power cut-off device and a suitable safety fuse (not delivered by EUREVIA).
  • Page 5 Diagram 1 0 to 1,5° Max Diagram 2 If it’s not pre-assembled in the factory EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 – www.eurevia.com...
  • Page 6: Return Air Plenum

    The inner and outer ducts of the double-skinned ducts must each be fastened with hose clamps. If it’s not pre-assembled in the factory EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...
  • Page 7: Air Duct Connections : Outlets Installation

    The hydraulic battery has a trap located at the top just above the water outlet. It’s visible and accessible without any need to dismantle the plant. EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...
  • Page 8: Hydraulic Outfits

    - Absorbed power at start-up: 36 W - Inrush current: 150 mA - Spring tension: 125 N EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...
  • Page 9: Té De Réglage

    - In/out ΔT° range : 2/90°C - Straight lengths recommended before the sensor: 110mm EUREVIA declines any responsibility on hydraulic equipment damage if it’s due to hydraulic network design problems or to human errors during commissioning EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...
  • Page 10: Electrical Protection

    Wounded Capilary isolated lenght 350 mm 350 mm The responsibility of EUREVIA cannot be engaged if problems due to an incorrect or non-existent grounding appears. 5. Starting Functional test - Make sure that the unit is correctly installed and placed (§2) and that the drainage pipe is not clogged EUREVIA - ZI Athélia 5 –...
  • Page 11: Use

    Insulation problem on the false Improve the insulation of the false ceiling ceiling EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 – www.eurevia.com...
  • Page 12: Care & Maintenance

    NB: it is essential to keep the support frame to install the new motor on the fancoil EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...
  • Page 13: Filter Remplacement

    - Disconnect the connections to the safety thermostat - Remove the resistances - Proceed in reverse order to put new resistances EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...
  • Page 14: Size And Maintenance

    (kg) (mm) blowing outlets (mm) cPIA 3 x Ø200 cPIA x Ø200 EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 – www.eurevia.com info@eurevia.com...
  • Page 15: Acces Maintenance

    ACCES MAINTENANCE FIXATIONS EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 – www.eurevia.com info@eurevia.com...
  • Page 16: Notes

    The installation and servicing of the equipment described in this manual must only be performed by qualified personnel EUREVIA - ZI Athélia 5 – 369 avenue des Grenadiers - 13600 La Ciotat - FRANCE Phone : +33 (0)4 42 70 70 30 –...