Step7- It is now time to pick up the test weight and raise to the weighing height
, (Raise to 1 , Lower to 2) . Allow approx 2-3 seconds for the weight to settle,
and then press the "Set Laden Calibration" key once.
Step8- Check the "Calculated Current Weight" screen to see if the weight
displays the test weight figure. If not, you may need to reset the Zero, Step 5,
and the Test Weight again.
Step 9 – Press the "Exit" button one press at a time to return to the main
weighing page and to save the calibration.
Perform as many test weighings until you are satisfied the system is working
correctly.
If at any time the indicator indicates an error message during the calibration
process, call your supplier for assistance. Before calling check that the
hydraulics have been installed into the correct 'LIFT' circuit of the machine,
and also check that your test weight is at least 1/3 - ½ machine capacity.