    5 Operation ........................6 Proper Operation ....................... 6 6 System Troubleshooting and Maintenance ............8 7 Schematics ........................ 9 AMCOL Corporation 21435 Dequindre, Hazel Park, MI 48030 248-414-5700 fax: 248-414-7489 www.amcolcorp.com P a g e | 1 6000-ETC Operator’s Manual...
  • Page 3: Introduction

    PLC. Reprogramming a PLC and installing additional hard wiring for the two-solenoid configuration is not always easy or efficient. To solve this problem, AMCOL has created a simple package to control a dual solenoid 6000E system with a single PLC output.
  • Page 4: Included Components

    2 Included Components Each 6000-ETC comes standard with the following components: 1. Preprogrammed Allen Bradley Micro800 Series PLC 2. 6’ grounded power cord with plug 3. Open cable gland to insert the machine PLC control output 4. NEMA 12/13 sealed steel electrical enclosure 5.
  • Page 5: Assembly And Installation

    WARNING! To protect the electronics from dust and other particles in the air, tighten all • cable glands, and do not leave the enclosure door open during normal operation. WARNING! AMCOL 6000-ETC systems are only designed to function with 6000E • applicators and correctly retrofitted 6000P applicators with dual solenoid controls. For installation instructions for 6000E applicators, see the 6000E Operator’s Manual.
  • Page 6: Recommended Settings

    Dispersing Air Injection Pulse Rate Solenoid (SV1) Solenoid (SV2) Item ID Description Recommended Setting Control Input Active when 6000E should be active Injection Rate According to machine cycle rate and volume P a g e | 5 6000-ETC Operator’s Manual...
  • Page 7: Operation

    • Press and hold the left button on the PLC inside the ETC enclosure. The system status will display manual. Manual operation should be used to verify current settings, test spray coating, and troubleshoot errors. P a g e | 6 6000-ETC Operator’s Manual...
  • Page 8 ETC. While running automatically, the spray volume and pattern should be consistent. No misting or fogging should be present. See the 6000E Operator’s Manual for troubleshooting spray output issues. P a g e | 7 6000-ETC Operator’s Manual...
  • Page 9: System Troubleshooting And Maintenance

    • Press any button on the PLC inside the ETC. • Turn the ETC off and on. Recommended Spares Description Part Number Quantity Lighted cap for solenoid 24VDC E-01013-61 110VAC E-01013-11 Cable gland 69915K54 P a g e | 8 6000-ETC Operator’s Manual...
  • Page 10: Schematics

    7 Schematics 6000-ETC-110 6000-ETC-24 6000-ETC-110-LLI 6000-ETC-24-LLI P a g e | 9 6000-ETC Operator’s Manual...