Page 1
U S E R I N S T R U C T I O N S A N D I N S T A L L A T I O N Version 2 11/01/22 Contents of manual may be updated without notice. For the latest version of this manual please refer to our website: www.paulagnewdesigns.com.au IMPORTANT NOTE...
USER MANUAL TERMS AND CONDITIONS WARRANTY CONTENTS 148 COCHRANES ROAD, MOORABBIN, VICTORIA 3189 THIS MANUAL COVERS THE FOLLOWING MODELS ONLY: FULL TERMS AND CONDITIONS ARE DETAILED 950A,1250 L,1650 L, 2000 L IN THE WARRANTY STATEMENT ON THE WEBSITE WWW.PAULAGNEWDESIGNS.COM.AU. A - ASPECT L - LANDSCAPE IN THE EVENT OF ANY CONFLICT OF INFORMATION THE WORDING ON THE WEBSITE...
Page 3
• WHERE THE ELECTRICITY SUPPLY CABLE HOW TO USE YOUR APPLIANCE HAS TO PASS THROUGH A MASONRY WALL, 1. IMPORTANT SAFETY STONE SURROUND ETC. ENSURE SUITABLE INFORMATION RUBBER BUSHES ARE FITTED AT POSSIBLE WEAR POINTS. • READ INSTRUCTIONS CAREFULLY BEFORE USING THE APPLIANCE. INSTRUCTIONS ARE AVAILABLE ONLINE AT WWW.PAULAGNEWDESIGNS.COM •...
Page 4
IF YOU ARE INSTALLING YOUR HOW TO USE YOUR APPLIANCE APPLIANCE IN TO AN EXISTING 1. IMPORTANT SAFETY CHIMNEY CAVITY INFORMATION • ENSURE THE FLOOR AREA THE APPLIANCE WILL SIT ON IS FLAT AND FREE FROM • IF THE ELECTRICITY SUPPLY CABLE IS LOOSE MATERIAL DAMAGED DO NOT USE THE APPLIANCE UNTIL IT HAS BEEN REPLACED.
• REGISTER WITH YOUR EMAIL ID OR MOBILE HOW TO USE YOUR APPLIANCE PHONE NUMBER AS THE USERNAME. 2. APP CONNECTING • PUT ANY 6 TO 20 DIGIT NUMBERS AS INSTRUCTIONS PASSWORD. • AGREE TO THE TERMS AND CONDITIONS. • DURING THE PROCESS YOU MAY BE ASKED APP DOWNLOAD TO ALLOW THE APP TO KNOW YOUR LOCATION.
Page 6
CONNECTING SUCCESSFULLY HOW TO USE YOUR APPLIANCE 2. APP CONNECTING THE FIREPLACE WILL DISPLAY “P4” AFTER INSTRUCTIONS YOUR FIREPLACE WELL CONNECTED. THE NAME OF THE FIREPLACE APPEARS ON THE CONNECTING PHONE. CLICK THE NAME OF THE ELCTRIC FIREPLACE TO ENTER THE OPERATION INTERFACE.
Page 7
• YOU CAN CHANGE THE COLOUR OF FUEL HOW TO USE YOUR APPLIANCE BED. 2. APP CONNECTING INSTRUCTIONS CONNECTING FAILURE • PLEASE REPEAT FROM STEP 1 TO STEP 4 FUNCTIONS LIGHT FUNCTIONS • YOU CAN CHANGE THE COLOUR AND BRIGHTNESS OF THE FLAME. •...
SOUND FUNCTION HOW TO USE YOUR APPLIANCE • YOU CAN ADJUST THE VOLUME OF 2. APP CONNECTING FIRE WOOD CRACKLING THROUGH THIS FUNCTION INSTRUCTIONS HEAT FUNCTION • CHOOSE FOR H1: 1KW OF HEAT OR H2: 2KW OF HEAT (H0: 0KW) TEMPERATURE FUNCTION •...
Page 9
❖ YOUR APP WILL AUTOMATICALLY TAKE THE DAY AND TIME FROM YOUR PHONE OR TABLET. IF YOU ARE SETTING YOUR FIRE UP IN A DIFFERENT TIME ZONE TO THE ONE YOUR PHONE OR TABLET WAS SET UP IN, THEN FIRST SELECT “DATE & TIME” FROM THE SETTINGS MENU AND CHOOSE THE TIME ZONE YOUR FIRE IS LOCATED IN.
Page 12
1. POWER SWITCH HOW TO USE YOUR APPLIANCE ON/OFF THE POWER 3. REMOTE CONTROL BUTTONS 2. FLAME BRIGHTNESS AND DISPLAY FIVE FLAME BRIGHTNESS SETTINGS: F5-F4-F3- F2-F1 3. COLOUR OF FLAME ORANGE; YELLOW; BLUE; ORANGE-YELLOW: YELLOW-BLUE; YELLOW-ORANGE-BLUE 4. BRIGHTNESS OF TOPLIGHT L5-L4-L3-L2-L1, L5 IS THE BRIGHTEST, L1 TURN OFF THE TOPLIGHT 5.
HOW TO USE YOUR APPLIANCE HOW TO USE YOUR APPLIANCE 4. OPERATING INSTRUCTIONS 5. MAINTENANCE AND CARE THE AIR INLET GRILLES ON THE TOPSIDE THERMAL SAFETY CUT OUT AND BACK OF THE APPLIANCE SHOULD BE IF THE SAFETY CUT OUT FOR THE HEATER UNOBSTRUCTED.
HOW TO USE YOUR APPLIANCE BATTERY REPLACEMENT 5. MAINTENANCE AND CARE REMOTE CONTROL BATTERY INFORMATION - SEE FIG. 35 CLEANING THE OUTLETS SLIDE OPEN THE BATTERY COVER ON • ENSURE THE APPLIANCE IS SWITCHED THE BACK OF THE REMOTE CONTROL OFF AT THE ISOLATION SWITCH INSTALL AAA BATTERIES INTO THE •...
HOW TO INSTALL YOUR APPLIANCE 6. TECHNICAL SPECIFICATION MODEL 950A 1250 L 1650L 2000L WEIGHT Kg VOLTAGE 230V 50Hz 230V 50Hz 230V 50Hz 230V 50Hz BATTERY HANDSET TRANSMITTER 12 V MN 21/23 12 V MN 21/23 12 V MN 21/23 12 V MN 21/23 FLAME PICTURE...
FITTING THE APPLIANCE HOW TO INSTALL YOUR APPLIANCE TAKE CARE WHEN LIFTING THE APPLIANCE, 7. GENERAL INSTALLATION OBTAIN ASSISTANCE IF REQUIRED AND ALWAYS FOLLOW SAFE MANUAL HANDLING TECHNIQUES. NOTE: INSTALLATION SHOULD BE CARRIED OUT BY A TRAINED INSTALLATION WHEN IN DOUBT CONSULT YOUR RETAILER OR TECHNICIAN.
Page 17
LOCATE THE BLANKING PLATE MOUNTING HOW TO INSTALL YOUR SCREWS ON EITHER SIDE OF THE APPLIANCE APPLIANCE. AS SHOW ON THE IMAGE 8. CONFIGURING YOUR WINDOW BELOW. • REMOVE THE 7 SCREWS USING THE CORRECT SCREWDRIVER. THE CONFIGURATION OF • RETAIN THE SCREWS FOR RE-ASSEMBLY. THE APPLIANCE MUST BE •...
• THE APPLIANCE SHOULD IDEALLY BE HOW TO INSTALL YOUR LOCATED CLOSE TO A SUITABLE MAINS APPLIANCE SOCKET TO ENABLE CONNECTION. THE 9. INSTALLATION ELECTRICAL SOCKET MUST BE EASILY ACCESSIBLE TO ALLOW DISCONNECTION WHEN THE APPLIANCE IS FITTED. POSITIONING YOUR APPLIANCE •...
Page 19
• REMOVE THE WALL BRACKET SCREWS AND HOW TO INSTALL YOUR ROTATE THE BRACKET AND ROTATE AS APPLIANCE SHOWN IN THE IMAGE BELOW 9. INSTALLATION • REATTACH THE BRACKETS AS SHOWN SO THEY ARE FLAT AGAINST THE FIXING WALL POSITIONING YOUR APPLIANCE AND ALIGN WITH THE MOUNT HOLES ON YOUR APPLIANCE.
Page 20
HOW TO INSTALL YOUR APPLIANCE 10. SETTING THE FUEL BED • LOG INSTALLATION IS TO BE CARRIED OUT • UNPACK THE BOX OF LOGS PROVIDED. THE BY A QUALIFIED INSTALLATION TECHNICIAN LOGS ARE MADE FROM CERAMIC AND ARE OR FOLLOW THE INSTRUCTIONS. FRAGILE.
Page 21
HOW TO INSTALL YOUR APPLIANCE 10. SETTING THE FUEL BED 950A LOG ARRANGEMENT- 9 PIECE LOG SET 1250L LOG ARRANGEMENT- 11 PIECE LOG SET 1650L LOG ARRANGEMENT - 13 PIECE LOG SET 2000L LOG ARRANGEMENT- 16 PIECE LOG SET...
HOW TO INSTALL YOUR • CONNECT THE POWER CABLE TO AN EARTHED SOCKET APPLIANCE 11. ELECTRICAL CONNECTION • ONLY USE THE POWER CABLE PROVIDED WITH YOUR APPLIANCE AS IT WILL BE WARNING CORRECT FOR YOUR REGION ENSURE THE APPLIANCE IS FULLY ASSEMBLED AND THE FRONT GLASS WITH TRIM IS BACK IN THE APPLIANCE BEFORE THE APPLIANCE IS CONNECTED...
Page 23
IF THE HEATER STOPS OPERATING WHILST SERVICING INSTRUCTIONS THE FLAME EFFECT CONTINUES NORMALLY, 12. GENERAL INFORMATION THIS INDICATES THAT THE E.S. CONTROL IS IN OPERATION. THE E.S. CONTROL CAN ONLY BE RE-SET THIS APPLIANCE MUST ONLY BE SERVICED AFTERTHE APPLIANCE HAS COOLED DOWN. BY A SUITABLY QUALIFIED PERSON.
Page 24
FAULT: THE HEATING DOES NOT TURN-ON SERVICING INSTRUCTIONS WHEN YOU SELECT HEATING MODE BUT THE 13. FAULT FINDING FLAME EFFECT IS RUNNING. CHECK THE BATTERIES IN YOUR HAND SET. THE RED LED MUST BE SHOWING BRIGHTLY. OPERATE APPLIANCE BEFORE COMMISSIONING TRY SELECTING HEATING MODE AGAIN, BUT CLOSER TO THE APPLIANCE.
Page 25
1. CLEAN THE EFFECTS SCREEN AND SERVICING INSTRUCTIONS OUTER SCREEN WITH SCREEN CLEANER 14. SERVICING REQUIREMENTS AND CLOTH. 2. CLEAN THE GLASS WITH GLASS CLEANER AND CLOTH. 3. CONNECT / RESTORE MAINS TO SERVICE THE APPLIANCE PLEASE ELECTRICITY AND ON/OFF SWITCH FOLLOW THE STEPS AS DETAILED: BACK-TO 1 POSITION.
Page 26
REMOVING THE TRIM BRACKETS SERVICING INSTRUCTIONS 15. REMOVING THE GLASS REMOVING THE FRONT TRIM USING A MAGNET, CAREFULLY LIFT THE FRONT TRIM IN THE CORNERS WARNING BEFORE UNDERTAKING ANY WORK ON THE APPLIANCE: SWITCH OFF THE APPLIANCE AND ISOLATE IT FROM THE MAINS BY UNPLUGGING THE UNIT.
Page 27
REMOVING THE GLASS SERVICING INSTRUCTIONS USING TWO GLASS LIFTING SUCTION PADS 15. REMOVING THE GLASS GRIP THE FRONT GLASS IN THESE LOCATIONS RELEASING THE GLASS WARNING: ALTHOUGH THE GLASS PANEL HAS BEEN TREATED WITH SAFETY EDGES PLEASE TAKE CARE WHEN HANDLING THE GLASS. AVOID CONTACT WITH CORNERS AND IF NECESSARY WEAR PROTECTIVE GLOVES.
Page 28
REFERENCE INFORMATION 16. WIRING DIAGRAM 28 8...
Page 29
REFERENCE INFORMATION 16. WIRING DIAGRAM...
Page 30
REFERENCE INFORMATION 16. WIRING DIAGRAM...
Page 31
REFERENCE INFORMATION 16. WIRING DIAGRAM...
Page 32
950A EXPLODED DIAGRAM REFERENCE INFORMATION 17. EXPLODED DIAGRAM...
Page 33
MODEL: 950A Part Number Description Part Number Description 010413710095 Wooden pallet 300000020400-R00 Flat bottom isolation column 100002857000 Backlight fixing panel 300000035000 Twin nose isolation column 100401960300 Movement fixing pane 300400330698 Fiberglass tube 100421840100-R00 Trumpet bracket 300400663026 Reflectors 100421930100-R01 Adaptor fixed box 300401060100-R00 Loudspeaker box 100421940100-R01...
Page 34
1250L EXPLODED DIAGRAM REFERENCE INFORMATION 17. EXPLODED DIAGRAM...
Page 36
1650L EXPLODED DIAGRAM REFERENCE INFORMATION 17. EXPLODED DIAGRAM...
Page 37
MODEL: 1650L Part Number Description Part Number Description 010413710165 Wooden pallet 300000020000 Flat bottom isolation column 100002857000 Backlight fixing panel 300000020400-R00 Flat bottom isolation column 100401960300 Movement fixing pane 300000035000 Twin nose isolation column 100421840100-R00 Trumpet bracket 300400331480 Fiberglass tube 100421930100-R01 Adaptor fixed box 300400663029...
Page 38
2000L EXPLODED DIAGRAM REFERENCE INFORMATION 17. EXPLODED DIAGRAM...
Page 39
Model 2000L Part Number Description Part Number Description 010413710200 Wooden pallet 300000020000 Flat bottom isolation column 100002857000 Backlight fixing panel 300000020400-R00 Flat bottom isolation column 100401960300 Movement fixing pane 300000035000 Twin nose isolation column 100421840100-R00 Trumpet bracket 300400331825 Fiberglass tube 100421930100-R01 Adaptor fixed box 300400663036...
Page 40
148 Cochranes Road Moorabbin, Victoria 3189 www.paulagnewdesigns.com.au info@paulagnewdesigns.com.au UK DISTRIBUTOR EUROSTOVE LTD Unit H1, Mendip Industrial Estate Mendip road Rooksbridge Somerset BS26 2UG www.eurostove.co.uk sales@eurostove.co.uk...