Programming The Unit - XGuard IntelliSwitch User Manual

Table of Contents

Advertisement

XGuard
IntelliSwitch

PROGRAMMING THE UNIT

The switch comes pre-programmed from factory for 2S LiPo
with audible warnings and switch active.
If you want to change the settings you can program the switch
for other battery types and to ignore the channel that activates
the locator if so wanted.
The switch has the following programmable settings:
A) Type of battery and warning or no warning:
• 1 beep) 2S LiPo Battery with Audible and LED Voltage Warnings
• 2 beeps) 2S LiPo Battery with only LED Voltage Warnings
• 3 beeps) 5cell NiMh Battery with Audible and LED Voltage Warnings
• 4 beeps) 5cell NiMh Battery with only LED Voltage Warnings
• 5 beeps) 2S LiFe Battery with Audible and LED Voltage Warnings
• 6 beeps) 2S LiFe Battery with only LED Voltage Warnings
B) Ignore the switch signal
• 7 beeps) Ignore Locator Alarm Switch Signal
Lipo Warning voltage: 6.7V (3.35V per cell)
Lipo Emergency voltage: 6.1V (3.05V per cell)
NiMh Warning voltage: 5.2V (1.04V per cell)
NiMh Emergency voltage: 4.8V (0.96V per cell)
LiFe Emergency voltage: 6.2V (3.1V per cell)