How to charge N
Be sure to use nitrogen gas only for the accumulator.
1.
Make sure that the release valve of accumulator
gas charging kit is tightened.
2.
Install a regulator in the N
connect a hose between the N
the accumulator gas charging kit.
Be sure to use a well-charged N
Important
cylinder that is over 6 MPa (870 psi).
3.
Loosen the regulator handle counterclockwise as
far as possible.
gas
2
gas cylinder, and then
2
gas cylinder and
2
Release
valve
gas
2