2. Remove plug 8 (with O-ring) on the upper side of
the accumulator cover.
Avoid facing plug 8. It could fly out and
cause serious personal injury.
3. Install the accumulator charging kit where plug 8
was screwed in.
Note:
If using the X type accumulator charging kit,
use the adapter (10942211). The handle for
the charging kit is not needed.
4. Make sure that the cap and the release valve
are tightened.
5. Gradually
turn
counterclockwise until the gauge reacts. Record
the gas pressure.
the
gas
charging
Cap
Release valve
valve