Mode : ; 0
Pulsed Delay, OFF with RESET
Start
Out1 & Out2 become ON "t.SEt" after
Reset
START input is triggered (OFF > ON).
t.SEt
START input can not re-trigger timer
Out1
until it is reset with RESET input. Out1
& Out2 are OFF when RESET input is ON.
t.SEt
Out2
Mode : ; 1
Flashing with START/RESET
Start
Reset
t.On
t.OFF
t.On
t.OFF
Out1
t.On
t.OFF
t.On
t.OFF
Out2
Mode : ; 2
One Shot after ON and OFF
Start
t.SEt
t.SEt
t.SEt
Out1
t.SEt
t.SEt
t.SEt
Out2
Mode : 3;
OFF Delay
Out1 & 2 become ON when START
Start
input is ON. Out1 & 2 become OFF
t.SEt
"t.SEt" after START input is triggered
Out1
(ON > OFF). Out1 & 2 are OFF when
t.SEt
RESET input is ON .
Out2
Notes:
1. For Mode1; t.On and t.OFF are accepted as min. 000.1 sec, 00.01 min. and 00.01 hr.
2. Timer counts up for Mode 6 & 7, and down for other modes.
3. For all modes; counting is inhibited (freeze) when GATE is ON.
Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean the device.
Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains
connections.
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti.
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye
Tel: +90-312-3503900, Fax: +90-312-3511117
MODES OF OPERATION
Out1 & Out2 are periodically first
ON for "t.On" and then OFF for
"t.OFF" after START input is
triggered (OFF > ON). Out1 & Out2
are OFF when RESET input is ON.
Out1 & 2 become ON when
START input is triggered
t.SEt
(OFF > ON) or (ON > OFF)
and become OFF after "t.SEt".
START input can re-trigger
t.SEt
when Out1 & 2 are ON.
Out1 & 2 are OFF when
RESET input is ON.
Mode : 4; Follow &
Start
Out1
t.SEt
Out2
Mode : ; 5
Delayed One Shot after OFF
Start
tA
Out1
tA
Out2
Mode : ; 6 Chronometer - Count with START
Start
t.SEt
Gösterge
Out1
Out2
Mode : ; 7 Chronometer-Count with START, Reset with RESET
Start
t.SEt
Gösterge
Out1
Out2
Reset
CLAEANING
4
ON Delay
Out1 is ON when Start input is ON.
Out2 becomes ON "t.SEt" after START
input is ON. Out1 & 2 are OFF when
START input is OFF. Out1 & 2 are OFF
when RESET input is ON .
Out1 & 2 are first ON after "tA" and then
tB
OFF after "tB" when START is triggered
(ON > OFF). START input does not
re-trigger before "tB" elapses. Out1 & 2
tB
are OFF when RESET input is ON.
Out is ON and timer counts up
1
when START is ON. Timer freezes
when START is OFF.
when timer elapses T.SEt.
resets and Out1
START is OFF after Timer elapses
T.SEt.
Out1 & 2 are OFF when
RESET input is ON.
Out is ON and timer counts up
1
when START is ON. Timer freezes
when START is OFF.
when timer elapses T.SEt.
resets and Out1
RESET input is ON.
http://www.gemo.com.tr
e-posta: info@gemo.com.tr
Out2 is ON
Timer
& 2 are OFF
when
Out2 is ON
Timer
& 2 are OFF when