Download Print this page

Gemo DZ961 Quick Start Manual

Digital timer

Advertisement

Quick Links

GEMO
GEMO
GEMO
GEMO
Attention
Risk of Danger,
Warning
Dimensions
Panel Cut-out
Display
Function
RESET Input
Scale
Resolution
Accuracy
Out Output
Supply Voltage
Power Consumption : < 6VA
Humidity
Altitude
EMC
Safety
Protection Class
Operation Temp.
Storage Temperature : -10
Weight
Key
Torque for screwing : Max. 0.5 N.m
no: normally open
nc: normally closed
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti.
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye
Tel: +90-312-3503900, Fax: +90-312-3511117
High Voltage,
Double / Reinforced
Risk of
Electric Shock
TECHNICAL SPECIFICATION
: 96x96mm
: 91x91mm
: 2x3 Digits 7 Segment
: Delayed output after RESET OFF
: 8 & 9 pins
: 99.9 minutes or 999 seconds (selectable)
: 0.1 minute or 1 second
: ± 1 % (Over full scale)
: Relay (NO-O-NC), 250VAC, 2A, Resistive load
: 100..240VAC, 50-60Hz
o
: 80% up to 30
C, then linearly decreases to 50% at 50
: < 2000 m
: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)
: EN 61010-1; Pollution degree 1, measurement category I, (Only light industrial
environment, double/reinforced isolated, non-conductive pollution environment)
: IP20; according to EN 60529
o
: 0 .. 50
C
o
o
C .. 60
C (no icing)
: < 0.5 kg
: Micro switch
Insulation
1
DZ961
DIGITAL TIMER
NOT
CE Mark
Litter
o
C (non-condensing)
http://www.gemo.com.tr
e-posta: info@gemo.com.tr

Advertisement

loading

Summary of Contents for Gemo DZ961

  • Page 1 DZ961 GEMO GEMO GEMO GEMO DIGITAL TIMER Attention High Voltage, Double / Reinforced CE Mark Risk of Danger, Risk of Insulation Litter Warning Electric Shock TECHNICAL SPECIFICATION • Dimensions : 96x96mm • Panel Cut-out : 91x91mm • Display : 2x3 Digits 7 Segment •...
  • Page 2 ● Use insulated cable end-sleeves at the end of cables screwed to the device connector terminals. ● Maximum torque for screwing; 0.5 N.m. ● Please check www.gemo.com.tr for latest device and documentation updates regularly. All updates and all information are subject to change without notice.
  • Page 3 RESET VIA FRONT PANEL Press “Up” and “Down” Keys at the same time for 2 seconds Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: info@gemo.com.tr Tel: +90-312-3503900, Fax: +90-312-3511117...
  • Page 4 Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains connections. Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: info@gemo.com.tr Tel: +90-312-3503900, Fax: +90-312-3511117...