Download Print this page

Gemo DZ304 Manual

Digital timer

Advertisement

Quick Links

GEMO
GEMO
GEMO
GEMO
Attention
Risk of Danger,
Warning
Dimensions
Panel Cut-out
Display
Inputs
GATE Input
Output
Time Base
Resolution
Accuracy
Modes
Sensor Supply Out
Supply Voltage
Power Consumption : < 6VA
Humidity
Altitude
EMC
Safety
Protection Class
Storage Temperature : -10
Operation Temp.
Weight
Key
Torque for screwing : Max. 0.5 N.m
no: normally open
nc: normally closed
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti.
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye
Tel: +90-312-3503900, Fax: +90-312-3511117
High Voltage,
Double / Reinforced
Risk of
Electric Shock
TECHNICAL SPECIFICATION
: 48x48mm
: 45,5x45,5mm
: 2x4 Digits 7 Segment
: START / RESET / GATE
3 x max. 32VDC (OFF:0..2VDC, ON:7..24VDC)
: Inhibits count-down/up when GATE is ON
: Out Relay (NO-O-NC), 250VAC, 2A, Resistive load
SS Out; open collector (NPN), 30V,100mA max.
: Selectable; 99:59 hours / 99:59 minutes / 599.9 seconds
: 1 min. / 1 sec./ 0.1 sec.
: ± 0,5 % (Over full scale)
: Selectable 13 different modes
: 12VDC, 50mA max. (unregulated)
: 100..240VAC, 50-60Hz or 24Vac/dc (optional)
o
: 80% up to 30
C, then linearly decreases to 50% at 50
: < 2000 m
: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)
: EN 61010-1; Pollution degree 1, measurement category I, (Only light industrial
environment, double/reinforced isolated, non-conductive pollution environment)
: IP20; according to EN 60529
o
o
C .. 60
C (no icing)
o
: 0 .. 50
C
: < 0.5 kg
: Micro switch
+12V 50mA
9
START
10
RESET
11
GATE
12
SS Out
13
Gnd
14
Insulation
+12V 50mA
9
START
10
RESET
11
GATE
12
13
SS Out
-
(*)
Gnd
14
START
+12V 50mA
Switch
START
RESET
RESET
Switch
GATE
SS Out
GATE
Switch
1
DZ304
DIGITAL TIMER
NOT
CE Mark
Litter
o
C (non-condensing)
(**) Use free-
(*) SS Out
wheeling diode
return should
to protect SS Out.
be
directl
y
connected to
GND pin.
+
(**)
PNP Proximity
+
9
Out
10
PNP Proximity
Out
11
+
Out
12
PNP Proximity
13
+ +
-
Gnd
14
http://www.gemo.com.tr
e-posta: info@gemo.com.tr
3 Vdc
2
(Max)
Switch
Switch
Switch

Advertisement

loading

Summary of Contents for Gemo DZ304

  • Page 1 DZ304 GEMO GEMO GEMO GEMO DIGITAL TIMER Attention High Voltage, Double / Reinforced CE Mark Risk of Danger, Risk of Insulation Litter Warning Electric Shock TECHNICAL SPECIFICATION • Dimensions : 48x48mm • Panel Cut-out : 45,5x45,5mm • Display : 2x4 Digits 7 Segment •...
  • Page 2 ● Use insulated cable end-sleeves at the end of cables screwed to the device connector terminals. ● Maximum torque for screwing; 0.5 N.m. ● Please check www.gemo.com.tr for latest device and documentation updates regularly. All updates and all information are subject to change without notice.
  • Page 3 Loads Timer value & OUT status at the latest power failure after the first power on. Prog. end Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: info@gemo.com.tr Tel: +90-312-3503900, Fax: +90-312-3511117...
  • Page 4 Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean the device. Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains connections. Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: info@gemo.com.tr Tel: +90-312-3503900, Fax: +90-312-3511117...