Dimensions
Panel Cut-out
Display
Inputs
GATE Input
Output
Time Base
Resolution
Accuracy
Modes
Supply Voltage
Power Consumption : < 6VA
Humidity
Altitude
EMC
Safety
Protection Class
Storage Temperature : -10
Operation Temp.
Weight
Key
Torque for screwing : Max. 0.5 N.m
no: normally open
nc: normally closed
Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti.
Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye
Tel: +90-312-3503900, Fax: +90-312-3511117
High Voltage,
Double / Reinforced
Risk of
Electric Shock
TECHNICAL SPECIFICATION
: 96x96mm
: 91x91mm
: 2x4 Digits 7 Segment
: START / RESET / GATE
3 x 230 VAC (0FF:0..50VAC, ON:150..240VAC)
: Inhibits count-down/up when GATE is ON
: Out1, Out2; 2 x Relay (NO-O-NC), 250VAC, 2A, Resistive load
: Selectable; 99:59 hours / 99:59 minutes / 599.9 seconds
: 1 min. / 1 sec./ 0.1 sec.
: ± 0,5 % (Over full scale)
: Selectable 8 different modes
: 100..240VAC, 50-60Hz
o
: 80% up to 30
C, then linearly decreases to 50% at 50
: < 2000 m
: EN 61000-6-1, EN 61000-6-3 (Only light industrial environment)
: EN 61010-1; Pollution degree 1, measurement category I, (Only light industrial
environment, double/reinforced isolated, non-conductive pollution environment)
: IP20; according to EN 60529
o
o
C .. 60
C (no icing)
o
: 0 .. 50
C
: < 0.5 kg
: Micro switch
Insulation
1
DZ309
DIGITAL TIMER
NOT
CE Mark
Litter
o
C (non-condensing)
http://www.gemo.com.tr
e-posta: info@gemo.com.tr

Advertisement

loading

Summary of Contents for Gemo DZ309

  • Page 1 DZ309 GEMO GEMO GEMO GEMO DIGITAL TIMER Attention High Voltage, Double / Reinforced CE Mark Risk of Danger, Risk of Insulation Litter Warning Electric Shock TECHNICAL SPECIFICATION • Dimensions : 96x96mm • Panel Cut-out : 91x91mm • Display : 2x4 Digits 7 Segment •...
  • Page 2 ● Use insulated cable end-sleeves at the end of cables screwed to the device connector terminals. ● Maximum torque for screwing; 0.5 N.m. ● Please check www.gemo.com.tr for latest device and documentation updates regularly. All updates and all information are subject to change without notice.
  • Page 3 Loads Timer value & OUT status at the latest power failure after the first power on. Prog. end Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: info@gemo.com.tr Tel: +90-312-3503900, Fax: +90-312-3511117...
  • Page 4 Do not use any solvents (alcohol, thinners, benzine, acid, etc.) or corrosive substances to clean the device. Use only a dry and clean non-abrasive cloth. Before cleaning, disconnect the power supply and mains connections. Gürbüzoğlu Elektronik San. ve Tic. Ltd. Şti. http://www.gemo.com.tr Çamlıtepe Cad. No:297 / 3-4 Siteler, Ankara, Türkiye e-posta: info@gemo.com.tr Tel: +90-312-3503900, Fax: +90-312-3511117...