DUAL AIR GAP INSTALLATION
1
2
3
4
PLUMBING & ELECTRICAL CONNECTION
We recommend installing a Dual
Air Gap Kit to your benchtop like
shown. This is the preferred Air Gap
installation method.
Refer to 'Plumbing & electrical
connection' for minimum install heights.
Thread wire clips on to the hoses before
fitting both hoses to the Dual Air Gap
Kit. Secure using the wire clips. Ensure
hoses are routed straight to the kit,
removing excess drain hose if necessary.
Unplug or drill out the waste tee before
securing to sink trap or waste tee.
Connect the inlet hose to tap and hand-
tighten into place.
Using a spanner or pliers, turn a further
180° to secure. Avoiding over-tightening.
Do not turn water supply on. The
DishDrawer™ Dishwasher must be
powered on for the flood protection
feature to be enabled.
Plug product in.
SINGLE AIR GAP INSTALLATION
1
2
3
4
Install your single Air Gap Kit to the
benchtop like shown.
Refer to 'Plumbing & electrical
connection' for minimum install heights.
Thread wire clips on to the hoses before
fitting both hoses to the supplied hose
joiner. Secure using the wire clips. Fit to
the Air Gap Kit. Ensure hoses are routed
straight to the joiner, removing excess
drain hose if necessary.
Unplug or drill out the waste tee before
securing to sink trap or waste tee.
Connect the inlet hose to tap and hand-
tighten into place.
Using a spanner or pliers, turn a further
180° to secure. Avoiding over-tightening.
Do not turn water supply on. The
DishDrawer™ Dishwasher must be
powered on for the flood protection
feature to be enabled.
Plug product in.